1_H24维修手册.pdf - 第20页

E d i ti o n 5 .0 H 24 H ead R ep ai r T r ai n i n g T ext f o r S er vi ce E n g i n ee r s R e p l a c i n g th e s y r i n g e s R e m ov e t he s y r i nge as s e m b l y f r o m t he he ad, and t hen c h ec k t hat…

100%1 / 214
Edition 5.0 H24 Head Repair Training Text for Service Engineers
Replacing the syringes
6. Set the head on a paper roll as shown below.
7. Pull the spring back and set the spring retainer jig on the syringe as shown below.
8. Use the lever jig and torque driver to loosen the nut on the old syringe.
Torque driver :
2AGKHJ01500*
Lever jig:
2AGKHJ00420*
1
2
3
Plate
FK-9F50-08-0E 1-3 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineers
Replacing the syringes
Remove the syringe assembly from the head, and then check that none of the parts shown
below are missing.
9. This completes the syringe removal procedure.
Syringe
shaft
Spring
Nut
Collar
Arm
Collar
Collar
Top gear
Bottom
gear
Gear
Spring
Do not need to
separate them,
when they are
not broken.
FK-9F50-08-0E 1-4 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineers
Replacing the syringes
1.2 Attaching the New Syringe
1. Apply a thin layer of Biral to the new syringe.
2. Set the new syringe in the rotary holder and use the digital force gauge to measure
the sliding resistance. Tolerance is 0.2 N or less.
3. Set the spring on the syringe as shown.
Tolerance: Within 0.2 N
Spring
FK-9F50-08-0E 1-5 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8