Edition 5.0 H24 Head Repair Training Text for Service Engineers
Replacing the syringes
12. Attach the lower collar, arm and upper collar. Make sure each part faces the correct
direction as shown.
13. Apply a small amount of Loctite 222 to the thread at the tip of the syringe. Be careful
not to apply too much. If glue drips onto the Q-axis gear it will interfere with the motion
of the gear.
Apply
Loctite 222
here
Attach the lower
collar, arm and
upper collar
FK-9F50-08-0E 1-10 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8

Edition 5.0 H24 Head Repair Training Text for Service Engineers
Replacing the syringes
14. Use the lever jig and torque driver to tighten the nut on the new syringe with 10
cN.m (0.1 N.m) torque force. Ensure the rounded surface of the nut is on top.
15. Remove the spring retainer jig(2AGTHJ002200).
16. The syringe should look like this once you have tightened the nut.
17. Reattach the covers.
18. This completes the syringe attachment procedure.
Top
Bottom
Torque driver:
2AGKHJ01500*
Lever jig:
2AGKHJ00420*
The completed
syringe looks
like this
FK-9F50-08-0E 1-11 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8

Edition 5.0 H24 Head Repair Training Text for Service Engineers
Replacing the syringes
MEMO:
FK-9F50-08-0E 1-12 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8