1_H24维修手册.pdf - 第28页

E d i ti o n 5 .0 H 24 H ead R ep ai r T r ai n i n g T ext f o r S er vi ce E n g i n ee r s R e p l a c i n g th e s y r i n g e s ME MO : F K - 9F 50 - 08 - 0E 1 - 12 F U JI M A CHI N E M F G . C O ., L T D. CONFIDENT…

100%1 / 214
Edition 5.0 H24 Head Repair Training Text for Service Engineers
Replacing the syringes
14. Use the lever jig and torque driver to tighten the nut on the new syringe with 10
cN.m (0.1 N.m) torque force. Ensure the rounded surface of the nut is on top.
15. Remove the spring retainer jig(2AGTHJ002200).
16. The syringe should look like this once you have tightened the nut.
17. Reattach the covers.
18. This completes the syringe attachment procedure.
Top
Bottom
Torque driver:
2AGKHJ01500*
Lever jig:
2AGKHJ00420*
The completed
syringe looks
like this
FK-9F50-08-0E 1-11 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineers
Replacing the syringes
MEMO:
FK-9F50-08-0E 1-12 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
C
C
h
h
a
a
p
p
t
t
e
e
r
r
2
2
R
R
e
e
p
p
l
l
a
a
c
c
i
i
n
n
g
g
t
t
h
h
e
e
Z
Z
-
-
a
a
x
x
i
i
s
s
m
m
o
o
t
t
o
o
r
r
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8