Edition 5.0 H24 Head Repair Training Text for Service Engineers
Replacing the Z-axis ball screw
11. Attach the Z-axis motor with the two bolts. When tightening them, align the motor shaft
so the coupling can slide up and down smoothly.
12. Temporally tighten the four coupling bolts. Tighten them completely when measuring
the proper data.
13. Attach the spool up/down arm assembly, bracket (upper), stepping motor, and IPS
camera using the reverse procedure to the one used when removing them.
Temporarily tighten the stepping motor and IPS camera.
14. Perform the Z-axis proper data measurement.
FK-9F50-08-0E
3-9
FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineers
Replacing the Z-axis ball screw
MEMO:
FK-9F50-08-0E
3-10
FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
C
C
h
h
a
a
p
p
t
t
e
e
r
r
4
4
R
R
e
e
p
p
l
l
a
a
c
c
i
i
n
n
g
g
t
t
h
h
e
e
R
R
-
-
a
a
x
x
i
i
s
s
m
m
o
o
t
t
o
o
r
r
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8