Edition 5.0
H24 Head Repair Training Text for Service Engineers
Adjusting the Nozzle Lowering Lever Check Sensor and Measuring the Air Pressure
6.3 Airflow Measurement
1. Set 0.7 mm nozzles on all the syringes except the one you will measure (23 syringes),
and then attach the head to the I/O check jig (AA1RS0*).
2. Raise all spool valves.
3. Attach the measurement jig (2AGKHJ015202) to the syringe to connect with the air flow.
Spool
Airflow
2AGKHJ01520
φ0.7 nozzle × 23
FK-9F50-08-0E
6-10
FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0
H24 Head Repair Training Text for Service Engineers
Adjusting the Nozzle Lowering Lever Check Sensor and Measuring the Air Pressure
4. Click [Vacuum Break].
5. Measure the airflow. (airflow: more than 0.1/min)
Note: The flow amount is reduced if any of the O-rings are damaged. Any damaged
O-rings should be replaced.
FK-9F50-08-0E
6-11
FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0
H24 Head Repair Training Text for Service Engineers
Adjusting the Nozzle Lowering Lever Check Sensor and Measuring the Air Pressure
6.4 Nozzle Cleaning Pressure Measurement and Air Flow
Measurement
[Nozzle cleaning pressure measurement]
1. Attach the vacuum pressure measurement jig (2AGKHJ015202) to the syringe to
connect with the manometer.
2. Raise all the spool valves.
3. Use IO check to turn nozzle cleaning ON.
4. Check that the nozzle cleaning pressure is more than 10 kPa.
[Nozzle cleaning airflow]
1. Attach the vacuum pressure measurement jig (2AGKHJ015202) to the syringe to
connect with the air flow.
2. Raise all the spool valves.
3. Use IO check to turn nozzle cleaning ON.
4. Check that the airflow is more than 2 L/min.
6.5 Vacuum Pressure Measurement
1. Attach the head I/O check jig to the head.
2. Raise all spool valves.
Spool
FK-9F50-08-0E
6-12
FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL