4OM-1840 1-4-36 1604-001 ( Y-Axis Cable Fixing Places Every 6 Months Inspection Required Time: 1 minute Y-Axis Cable Side Faces Every 6 Months Cleaning and Lubrication (BARRIERTA IEL/V) Required Time: 3 minutes Fig. 4A4-…

100%1 / 315
4OM-1840
1-4-351604-001
4.8 X/Y Beam Section
X-Axis Linear Guides (4 locations)
Every Day Inspection
Required Time: 1 minute
X-Axis Linear Guides (4 locations)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Y-Axis Linear Guides (4 locations)
Every Day Inspection
Required Time: 1 minute
Y-Axis Linear Guides (4 locations)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Fig. 4A4-45
4.8 X/Y Beam Section
4OM-1840
1-4-361604-001
(
Y-Axis Cable Fixing Places
Every 6 Months Inspection
Required Time: 1 minute
Y-Axis Cable Side Faces
Every 6 Months Cleaning and Lubrication
(BARRIERTA IEL/V)
Required Time: 3 minutes
Fig. 4A4-46
6
Y-Axis Linear Scale
Every 6 Months Cleaning
Required Time: 5 minutes
Fig. 4A4-47
4.8 X/Y Beam Section
4OM-1840
1-4-371604-001
4.8.1 X-axis Linear Guide Check
Cycle : Every Day (Required Time : 1 minute)
X-Axis Linear Guides
Fig. 4A4-48
Procedure
Check it visually that no alien substance has been dropped. If any alien substance
has been dropped, remove it.