4OM-1840 1-4-51 1604-001 4.10.3 PCB Detection Sensor Cleaning Cycle : Every Week (Required Time : 2 minutes) PCB Detection Sensor The light receiving section is located inside these sections in the figure. Fig. 4A4-63 Pr…

100%1 / 315
4OM-1840
1-4-501604-001
4.10.2 Support Pin Detection Sensor Cleaning
Cycle : Every Week (Required Time : 1 minute)
Support Pin Detection Sensor
Fig. 4A4-62
Procedure
Clean the support pin detection sensors with a rag.
Note
Perform the cleaning operation using the same procedure also in the system where the
Y510 mm Single Transfer Unit (Factory option) has been mounted.
4.10 Conveyor Section
4OM-1840
1-4-511604-001
4.10.3 PCB Detection Sensor Cleaning
Cycle : Every Week (Required Time : 2 minutes)
PCB Detection Sensor
The light receiving section is
located inside these sections
in the figure.
Fig. 4A4-63
Procedure
Clean the PCB detection sensor light emitting and receiving sections using a rag.
Note
Perform the cleaning operation using the same procedure also in the system where the
Y510 mm Single Transfer Unit (Factory option) has been mounted.
4.10 Conveyor Section
4OM-1840
1-4-521604-001
4.11 Nozzle Stocker Section
Nozzle Storage Section
Every Month Cleaning
Shutter Flange Pin Sliding Section
Every 3 Months Cleaning and Lubrication
(MOLYNOC GREASE AP1)
Required Time: 5 minutes
Nozzle Stocker Sliding Section
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Fig. 4A4-65
4.11 Nozzle Stocker Section