4M184002w_F8S - 第128页

4OM-1840 1-4-53 1604-001 4.1 1.1 Shutter Flange Pin Sliding Section Cycle : Every 3 Months (Required Time : 5 minutes) Grease : MOLYNOC GREASE AP1 Shutter Flange Pin Sliding Section Fig. 4A4-66 Procedure    …

100%1 / 315
4OM-1840
1-4-521604-001
4.11 Nozzle Stocker Section
Nozzle Storage Section
Every Month Cleaning
Shutter Flange Pin Sliding Section
Every 3 Months Cleaning and Lubrication
(MOLYNOC GREASE AP1)
Required Time: 5 minutes
Nozzle Stocker Sliding Section
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Fig. 4A4-65
4.11 Nozzle Stocker Section
4OM-1840
1-4-531604-001
4.11.1 Shutter Flange Pin Sliding Section
Cycle : Every 3 Months (Required Time : 5 minutes)
Grease : MOLYNOC GREASE AP1
Shutter Flange Pin Sliding Section
Fig. 4A4-66
Procedure
 
(2) Apply new grease using a syringe.
4.11 Nozzle Stocker Section
4OM-1840
1-4-541604-001
4.11.2 Nozzle Storage Section
Cycle : Every Month
Nozzle Storage Section
Fig. 4A4-67
Procedure
Suck dirt and dust with a vacuum cleaner.
4.11 Nozzle Stocker Section