Error ID Error Name, Description, Cause, and Remedy 40081E Servo Alarm Initial Communication Error of Detector(2) Error of connection to Detector . Please check wiring. 40081F Servo Alarm Initial Communication Error of D…

Error ID Error Name, Description, Cause, and Remedy
4007B0 Operation Alarm
No Available Servo control
Please check whether there is connection to Servo Amplier or not.
Please check System Error on Machine check screen about specication of
Communication Error.
4007B1 Operation Alarm
On Servo Alarm
Please operate after cancelling Servo alarm
4007B2 Operation Alarm
On Servo O
Please operate after setting Servo [On]
4007B3 Operation Alarm
Command of Servo O
There was Servo O command during operation
400810 Servo Alarm
Insucient voltage
The Power is dropped/disconnected foe moment.
Please check wiring and power supply.
400812 Servo Alarm
Memory Error1(RAM)
Servo Amplier is broken. Exchange it.
400813 Servo Alarm
Clock Error
Servo Amplier or Position Port is broken. Exchange it
400815 Servo Alarm
Memory Error2(EEPROM)
EEPROM of Servo Amplier is broken. Exchange it.
400816 Servo Alarm
Detector Error1
Error of connection to Detector. Please check wiring.
400817 Servo Alarm
Control Board Error
Exchange Servo Amplier.
400819 Servo Alarm
Memory Error3(FlashROM)
Exchange Servo Amplier.
40081A Servo Alarm
Motor Combination Error
Could not recognize connected Motor.
Please update the version of Servo Amplier.
40081C Servo Alarm
Software Combination Error
Could not recognize connected Motor.
Please update the version of Servo Amplier.
3.1 Safety Device
4OM-1840
3-3-51604-001

Error ID Error Name, Description, Cause, and Remedy
40081E Servo Alarm
Initial Communication Error of Detector(2)
Error of connection to Detector. Please check wiring.
40081F Servo Alarm
Initial Communication Error of Detector(3)
Error of connection to Detector. Please check wiring.
400820 Servo Alarm
Detector Error2
Error of connection to Detector. Please check wiring.
400821 Servo Alarm
Detector Communication Error(2)
Error of connection to Detector. Please check wiring.
400824 Servo Alarm
Main Circuit Error
Please exchange Servo Amplier if no error after checking Motor Power line and
Power Supply input line.
400825 Servo Alarm
Abs. Position Disappear
Please set Linear Scale, and then perform XY-axis Origin Oset Teaching.
400827 Servo Alarm
Initial magnetic detect Error
Please check whether it is close to Limit Sensor or not. there is any pressure from
outside, or the ambience is vibrating
400828 Servo Alarm
Linear Encoder Error2
Please check whether the temperature is high or not,
40082A Servo Alarm
Linear Encoder Error1
Please check whether there is no error in placement of Linear Encoder or not.
400830 Servo Alarm
Regenerative Error
Please drive with blocking tact. Or, exchange Servo amplier
400831 Servo Alarm
Fault speed
Please conrm that Motor Power Line and Encoder Line have error or not.
400832 Servo Alarm
Over-current
Please conrm that Motor Power Line has error or not.
400833 Servo Alarm
Fault voltage
Please conrm that there is any error in Primary Power Supply Voltage or not.
400834 Servo Alarm
Receiving Signal1
Is there any cable twisted or bent? If it does, Check it.
3.1 Safety Device
4OM-1840
3-3-61604-001

Error ID Error Name, Description, Cause, and Remedy
400835 Servo Alarm
Command Frequency Error
Exchange Position Board
400836 Servo Alarm
Error received data.
Is there any cable twisted or bent? Check it.
400837 Servo Alarm
Parameter Error
Check Servo parameter. Exchange Servo Amplier if no problem with Servo
parameter.
400842 Servo Alarm
Linear Servo control error detected
Is there any error of setup Linear Encoder or wiring of Power Line? Check it.
400845 Servo Alarm
Main circuit elem overheat
Drive with blocking tact, or take the ambient temperature of the Amplier down.
400846 Servo Alarm
Servo Motor overheat
Drive with blocking tact, or take the ambient temperature of the Motor down.
400847 Servo Alarm
Cooling Fan Error
Exchange cooling fan of Servo Amplier
400850 Servo Alarm
Overload1
Please check whether there is no error in Sliding detect of a driving system or in
motor wiring or not.
400851 Servo Alarm
Overload2
Please check whether there is no error in Sliding detect of a driving system or in
motor wiring or not.
400852 Servo Alarm
Error in excess
Please check whether there is no error in Sliding detect of a driving system or in
motor wiring or not.
40088A Servo Alarm
USB communication time-out
-----
40088B Servo Alarm
USB Communication Error
-----
400891 Servo Alarm
Multi-axes Amplier Temperature warning
Take the ambient temperature of the multi-axes amplier down.
3.1 Safety Device