Error ID Error Name, Description, Cause, and Remedy 4201 16 Backup(L) Error Limit Sensor(+) of Backup(L) axis is detected +LS signal was detected for moving for (+). Please check the dirt of +LS sensor , disconnection. 4…

Error ID Error Name, Description, Cause, and Remedy
420105 Backup(L) Error.
Time Over of the upward movement of stopper (L)
1. Check out the P.C.B. between stopper and conveyor
2. Error in Up/Down detection sensor. Check out the sensor input
3. Disconnection, Error of Movement output. Please check Stopper by manual
movement if sensor input is proper.
4. Please set speed again by adjusting speed control when stopper is slow.
420106 Backup(L) Error.
Time-over of downward Stopper(L)
1. Up/Down Detect Sensor is out of order. Please check Sensor input
2. Disconnection/Error of output. Please check Stopper by manual movement if
sensor input is proper.
3. Please set speed again by adjusting speed control when stopper is slow.
420107 Backup(L) Error.
Communication Error of the command of P.C.B. positioning (Backup)
Error in Motor Driver, Communications trouble(AE-LINK), Error in Communication
P.C.B.(API). Check out the wiring of Communication line, power supply line.
420108 Backup(L) Error.
Backup Pin/Jig under the conveyor belt is detected.
Check out the interference in Belt on Backup Base does not exist.
420110 Backup (L) Error
Not ready for System setup of Backup (L) axis
Driver has not completed the parameter setup yet. It is a situation in which a
correct setup has not been received by Communication Error.
Check the Communication Mode, wiring, Power supply of Driver.
420111 Backup(L) Error
Error in zeroing in Backup(L) axis
LS, discontinuous zeroing movement, was detected. Check out the dirt, error of
sensor and error in Motor body etc.
420112 Backup(L) Error
Out-of-Control in Backup(L) axis is detected
Motor Out-of-Control which is over the width of Out-of-Control detecting occurred.
Please execute all zeroing again, and the restart production. Please set motor
speed slow if it happens frequently. Also, in a case of structure motor Error.
420113 Backup(L) Error
Error in motor power voltage of Backup(L) axis
Motor power voltage dropped. Check out the Power supply line(48V Line)
420114 Backup(L) Error
STP input of Backup(L) Axis is detected
STP input is detected. The function to stop motor by Hard signal.
420115 Backup(L) Error
Over-current of Backup(L)
Error in Motor output line. Check out the motor wiring.
3.3 Conveyor
4OM-1840
3-3-221604-001

Error ID Error Name, Description, Cause, and Remedy
420116 Backup(L) Error
Limit Sensor(+) of Backup(L) axis is detected
+LS signal was detected for moving for (+).
Please check the dirt of +LS sensor, disconnection.
420117 Backup(L) Error
Limit Sensor(-) of Backup(L) axis is detected
-LS signal was detected for moving for (-).
Please check the dirt of -LS sensor, disconnection.
420118 Backup(L) Error
Disconnecting Motor of Backup(L) axis is detected.
Disconnection to motor was detected.(Only stop mode)
Check the motor wiring.
420119 Backup(L) Error
Error in the Control Power Voltage of Backup(L) axis
Control power for driver dropped. Check out the Power supply line.(24V Line)
42011a Backup(L) Error
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42011b Backup(L) Error
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42011c Backup(L) Error
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42011d Backup(L) Error
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42011e Backup(L) Error
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42011f Backup(L) Error
System Error of Backup(L) axis
System Error of internal driver. Driver error is supposed if this problem happens
frequently.
420120 Backup(L) Error
Communication Error of the Backup(L) axis
1. Conrm connection to communication cable.
2. Conrm Power supply(24V).
3. Conrm the communication setting of PCI board.
4. Conrm the address of driver and communication rate setting.
420131 Backup(L) Error
Failed to adsorb PCB.
Please check the status of PCB, and perform positioning again.
3.3 Conveyor
4OM-1840
3-3-231604-001

Error ID Error Name, Description, Cause, and Remedy
420132 Backup(L) Error
Failed to adsorb o of PCB.
Please check the status of PCB, and perform to release positioning again.
420133 Backup(L) Error
Adsorb of PCB was o during the production.
Please check the status of PCB, and perform positioning again.
420201 Backup(R) Error.
The Backup(R) Axis was not completed within predetermined time.
Backup axis is unable to do upward movement and down movement.
The factor is for Motor, Driver, Sensor Error or wiring Error.
Please check the motor, sensor on Machine check screen.
420202 Backup(R) Error.
Driver Alarm on Backup(R) Axis
Conrm reset Method of detailed Sub-system error counts of Alarm.
420203 Backup(R) Error.
Error in calculating data of positioning command of Backup(R) Axis
Please conrm the following data.
1. Machine Oset/Backup Pin(Up/Down)
2. Pattern Program/P.C.B. Information/P.C.B. size/Thickness
3. Control/Common/PRE-PLACED CMPNT THKNS/Bottom of P.C.B.
420204 Backup(R) Error.
Time-over of zeroing of Backup(R) Axis
Check out the dirt, error, disconnection of sensor. If there is no problem with
sensor, the problem could be with motor wire/single error.
420205 Backup(R) Error.
Time-over of the upward movement of stopper(R)
1. Please conrm whether P.C.B. is caught between stopper and conveyor.
2. Error in Up/Down detecting sensor. Please check sensor input.
3. Disconnection/Error of Output. Please conrm the stopper by manual if sensor
input is correct.
4. Please reset the speed by adjusting speed control when stopper is slow.
420206 Backup(R) Error.
Time-over of the downward movement of stopper(R)
1. Error in Up/Down detecting sensor. Conrm the sensor.
2. Disconnection/Error of Output. Please conrm the stopper by manual if sensor
input is correct.
3. Please reset the speed by adjusting speed control when stopper is slow.
420207 Backup(R) Error.
Communication Error of the command movement of P.C.B. positioning(Backup)
Motor Driver Error Trouble in communication system(AE-LINK), possibility of Error
of communication P.C.B.(API).
Please conrm wiring of communication line and Power line.
420208 Backup(R) Error.
Backup Pin/Jig under the conveyor belt is detected.
Check out the interference in Belt on Backup Base does not exist.
3.3 Conveyor