4M184002w_F8S - 第208页

Error ID Error Name, Description, Cause, and Remedy 427101 Detection of Output conveyor sensor Decrease sensor was detected before starting. There is an indenite P .C.B. on Output conveyor . Please remove it. 427102 Det…

100%1 / 315
Error ID Error Name, Description, Cause, and Remedy
426114 Detection of positioning conveyor sensor
PCB has now reached input position.
1. There is a possibility that PCB is inserted and is dropped from conveyor.
Please check the conveyor.
2. Please clear the PCB memory information in the edit screen if it is on the input
conveyor. Or, return the removed PCB."
426201 positioning conveyor timeout
Placement for input position was not completed within predetermined time.
1. There is a possibility that PCB is inserted between Input conveyor and Input
position or is dropped. Please conrm Input ~ positioning conveyor.
2. Please clear the PCB memory information in the edit screen if it is on the input
conveyor. Or, return the removed PCB.
3. Please check if cutout is on PCB. Please set cutout size in pattern program if
cutout is on PCB.
426202 positioning conveyor timeout
Output from input position was not completed within predetermined time.
1. There is a possibility that PCB is inserted between Input position and Output,
or is dropped. Please conrm positioning ~ output conveyor.
2. Please clear the PCB memory information in the edit screen if it is on the input
position. Or, return the removed PCB.
426203 positioning conveyor timeout
Placement for output position was not completed within predetermined time.
1. There is a possibility that PCB to take in the output position is inserted or
dropped. Please conrm input ~ positioning conveyor.
2. The state of PCB memory on the conveyor diers from the state of taking.
Please clear the PCB memory in the edit screen when if it is. Or, return the
removed PCB.
3. Please check if cutout is on PCB. Please set cutout size in pattern program if
cutout is on PCB.
426204 positioning conveyor timeout
Output from output position was not completed within predetermined time.
1. There is a possibility that PCB is inserted between Input position and Output,
or is dropped. Please conrm positioning ~ output conveyor.
2. Please clear the PCB memory information in the edit screen if it is on the
output position. Or, return the removed PCB.
426205 positioning conveyor timeout
Positioning was not completed within the predetermined time.
There is a possibility that PCB is inserted. Please check the PCB on the conveyor.
426301 positioning conveyor Error
Error in positioning conveyor
-----
426302 positioning conveyor Error
Error in positioning change.
Please check the PCB on the conveyor.
3.3 Conveyor
4OM-1840
3-3-461604-001
Error ID Error Name, Description, Cause, and Remedy
427101 Detection of Output conveyor sensor
Decrease sensor was detected before starting.
There is an indenite P.C.B. on Output conveyor. Please remove it.
427102 Detection of Output conveyor sensor
Decrease sensor was not detected before starting the movement
P.C.B. to output is not found
1. Please put P.C.B. on Sensor.
2. There is a possibility of P.C.B. fallen. Conrm the conveyor width.
427103 Detection of Output conveyor sensor
Stop sensor was detected before starting.
There is an indenite P.C.B.. Please remove it.
427104 Detection of Output conveyor sensor
Stop sensor was not detected before starting.
Cannot nd P.C.B. to output.
1. Is P.C.B. detected by sensor?
2. There is a possibility that P.C.B. is falling. Please check the width of conveyor.
427105 Detection of Output conveyor sensor
P.C.B. on decrease sensor was detected after movement completion
There is an indenite P.C.B. on Output conveyor. Please remove it.
427106 Detection of Output conveyor sensor
P.C.B. on decrease sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly. Check whether the sensor
doesn’t have Error.
427107 Detection of Output conveyor sensor
P.C.B. on stop sensor was detected after movement completion
There is an indenite P.C.B. on Output conveyor. Please remove it.
427108 Detection of Output conveyor sensor
P.C.B. on stop sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly. Check whether the sensor
doesn’t have Error.
427109 Detection of Output conveyor sensor
P.C.B. on output conveyor was detected
Please remove P.C.B. from the conveyor
42710a Detection of Output conveyor sensor
P.C.B. on output conveyor was not detected
Please check whether P.C.B. is detected correctly.
Check whether the sensor doesn’t have Error.
42710b Detection of Output conveyor sensor
Stop sensor is not passed during Output operation
The conveyor is stopped before P.C.B. goes through Sensor.
1. Conrm output method, transition speed, timer setting.
2. Check the connected cable.
3.3 Conveyor
4OM-1840
3-3-471604-001
Error ID Error Name, Description, Cause, and Remedy
42710c Detection of Output conveyor sensor
Disengaged P.C.B. of output conveyor
P.C.B. was removed from Output Conveyor.
Please check the state of it if removing P.C.B. does not happen intentionally.
42710d Detection of Output conveyor sensor
P.C.B. was not inserted into output conveyor
Please Remove P.C.B. inserted.
427201 Output conveyor timeout
Placement was not completed within predetermined time.
1. There is a possibility that PCB is caught, or dropped from Conveyor. Please
check the above conveyor.
2. The state of PCB memory on the conveyor diers from the state of taking.
Please clear the PCB memory in the edit screen when if it is. Or, return the
removed PCB.
427202 Output conveyor timeout
Output was not completed within predetermined time.
1. There is a possibility that PCB is caught, or dropped from Conveyor. Please
check the transition with Output Machine.
2. Please clear the PCB memory information in the edit screen on the output
conveyor if it is. Or, return the removed PCB.
427301 Output Conveyor Error
Error while output conveyor is moving.
-----
427401 Middle Conveyor Error
Time-out in Placement from Input Machine.
PCB is not placed in Device. Please check Middle Conveyor.
1. Whether Emergency stop is pressed
2. Whether Safety Cover is open
3. Whether Breaker is falling down
If PCB is on Middle Conveyor, whether remove it, or put it on Input conveyor.
427402 Middle Conveyor Error
Time-out in Output for Output Machine.
PCB is not outputted from Device. Please check Middle conveyor.
1. Whether Emergency stop is pressed
2. Whether Safety Cover is open
3. Whether Breaker is falling down
428001 Error in the communication of P.C.B. transfer
Input Machine signal cutting
A signal of work request for the output machine was cut o while P.C.B. is placing.
1. Please check the transfer method of Input Machine.
2. Check the connected cable.
3.3 Conveyor
4OM-1840
3-3-481604-001