4M184002w_F8S - 第209页

Error ID Error Name, Description, Cause, and Remedy 42710c Detection of Output conveyor sensor Disengaged P .C.B. of output conveyor P .C.B. was removed from Output Conveyor . Please check the state of it if removing P .…

100%1 / 315
Error ID Error Name, Description, Cause, and Remedy
427101 Detection of Output conveyor sensor
Decrease sensor was detected before starting.
There is an indenite P.C.B. on Output conveyor. Please remove it.
427102 Detection of Output conveyor sensor
Decrease sensor was not detected before starting the movement
P.C.B. to output is not found
1. Please put P.C.B. on Sensor.
2. There is a possibility of P.C.B. fallen. Conrm the conveyor width.
427103 Detection of Output conveyor sensor
Stop sensor was detected before starting.
There is an indenite P.C.B.. Please remove it.
427104 Detection of Output conveyor sensor
Stop sensor was not detected before starting.
Cannot nd P.C.B. to output.
1. Is P.C.B. detected by sensor?
2. There is a possibility that P.C.B. is falling. Please check the width of conveyor.
427105 Detection of Output conveyor sensor
P.C.B. on decrease sensor was detected after movement completion
There is an indenite P.C.B. on Output conveyor. Please remove it.
427106 Detection of Output conveyor sensor
P.C.B. on decrease sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly. Check whether the sensor
doesn’t have Error.
427107 Detection of Output conveyor sensor
P.C.B. on stop sensor was detected after movement completion
There is an indenite P.C.B. on Output conveyor. Please remove it.
427108 Detection of Output conveyor sensor
P.C.B. on stop sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly. Check whether the sensor
doesn’t have Error.
427109 Detection of Output conveyor sensor
P.C.B. on output conveyor was detected
Please remove P.C.B. from the conveyor
42710a Detection of Output conveyor sensor
P.C.B. on output conveyor was not detected
Please check whether P.C.B. is detected correctly.
Check whether the sensor doesn’t have Error.
42710b Detection of Output conveyor sensor
Stop sensor is not passed during Output operation
The conveyor is stopped before P.C.B. goes through Sensor.
1. Conrm output method, transition speed, timer setting.
2. Check the connected cable.
3.3 Conveyor
4OM-1840
3-3-471604-001
Error ID Error Name, Description, Cause, and Remedy
42710c Detection of Output conveyor sensor
Disengaged P.C.B. of output conveyor
P.C.B. was removed from Output Conveyor.
Please check the state of it if removing P.C.B. does not happen intentionally.
42710d Detection of Output conveyor sensor
P.C.B. was not inserted into output conveyor
Please Remove P.C.B. inserted.
427201 Output conveyor timeout
Placement was not completed within predetermined time.
1. There is a possibility that PCB is caught, or dropped from Conveyor. Please
check the above conveyor.
2. The state of PCB memory on the conveyor diers from the state of taking.
Please clear the PCB memory in the edit screen when if it is. Or, return the
removed PCB.
427202 Output conveyor timeout
Output was not completed within predetermined time.
1. There is a possibility that PCB is caught, or dropped from Conveyor. Please
check the transition with Output Machine.
2. Please clear the PCB memory information in the edit screen on the output
conveyor if it is. Or, return the removed PCB.
427301 Output Conveyor Error
Error while output conveyor is moving.
-----
427401 Middle Conveyor Error
Time-out in Placement from Input Machine.
PCB is not placed in Device. Please check Middle Conveyor.
1. Whether Emergency stop is pressed
2. Whether Safety Cover is open
3. Whether Breaker is falling down
If PCB is on Middle Conveyor, whether remove it, or put it on Input conveyor.
427402 Middle Conveyor Error
Time-out in Output for Output Machine.
PCB is not outputted from Device. Please check Middle conveyor.
1. Whether Emergency stop is pressed
2. Whether Safety Cover is open
3. Whether Breaker is falling down
428001 Error in the communication of P.C.B. transfer
Input Machine signal cutting
A signal of work request for the output machine was cut o while P.C.B. is placing.
1. Please check the transfer method of Input Machine.
2. Check the connected cable.
3.3 Conveyor
4OM-1840
3-3-481604-001
Error ID Error Name, Description, Cause, and Remedy
428002 Error in the communication of P.C.B. transfer
Output Machine signal cutting
A signal of work request for the output machine was cut o while P.C.B. is placing.
1. Please check the transfer method of output Machine.
2. Check the connected cable.
428101 Line PCB transfer error
Time-out of Placement
Line PCB transfer was not completed in prescribed time.
1. There is a possibility that PCB is caught. Please Check the Conveyor.
2. Please conrm whether Connect cable is normally connected or not.
428201 Transfer Error between Devices
Time-out of starting Input Machine
Could not start Output from Input Machine. Error in Input Machine.
428202 Transfer Error between Devices
Time-out of starting Output Machine
Could not receiver Start Signal from Output Machine. Error in output Machine.
428203 Transfer Error between Devices
Output Machine Error
Error during placement of Output Machine. Transfer will be stopped.
429001 Manual transfer Error
Time-out in Conveyor
The Conveyor didn't stop within predetermined time.
Please conrm the state of transfer driver.
42a001 Shuttle Conveyor Communication Error
Failed in getting Shuttle Conveyor Control Information.
Communication Error between CPU1 and CPU2 has occurred.
Please restart Machine.
42a101 Detect Suttle Conveyor Sensor in Input side
Decrease Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42a102 Detect Suttle Conveyor Sensor in Input side
Decrease Sensor is not detected before starting to operate.
PCB to insert is not found inner Machine.
1. Please put PCB on Sensor.
2. There is a possibility that PCB drops. Please check out Conveyor width.
42a103 Detect Suttle Conveyor Sensor in Input side
Stop Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42a104 Detect Suttle Conveyor Sensor in Input side
Stop Sensor is not detected before starting to operate.
PCB to insert is not found inner Machine.
1. Please conrm whether PCB is detected by Sensor or not.
2. There is a possibility that PCB drops. Please check out Conveyor width.
3.3 Conveyor
4OM-1840
3-3-491604-001