Error ID Error Name, Description, Cause, and Remedy 42a105 Detect Suttle Conveyor Sensor in Input side PCB is detected from Decrease Sensor after nishing completely . Please remove PCB from Shuttle Conveyor . 42a106 Det…

100%1 / 315
Error ID Error Name, Description, Cause, and Remedy
428002 Error in the communication of P.C.B. transfer
Output Machine signal cutting
A signal of work request for the output machine was cut o while P.C.B. is placing.
1. Please check the transfer method of output Machine.
2. Check the connected cable.
428101 Line PCB transfer error
Time-out of Placement
Line PCB transfer was not completed in prescribed time.
1. There is a possibility that PCB is caught. Please Check the Conveyor.
2. Please conrm whether Connect cable is normally connected or not.
428201 Transfer Error between Devices
Time-out of starting Input Machine
Could not start Output from Input Machine. Error in Input Machine.
428202 Transfer Error between Devices
Time-out of starting Output Machine
Could not receiver Start Signal from Output Machine. Error in output Machine.
428203 Transfer Error between Devices
Output Machine Error
Error during placement of Output Machine. Transfer will be stopped.
429001 Manual transfer Error
Time-out in Conveyor
The Conveyor didn't stop within predetermined time.
Please conrm the state of transfer driver.
42a001 Shuttle Conveyor Communication Error
Failed in getting Shuttle Conveyor Control Information.
Communication Error between CPU1 and CPU2 has occurred.
Please restart Machine.
42a101 Detect Suttle Conveyor Sensor in Input side
Decrease Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42a102 Detect Suttle Conveyor Sensor in Input side
Decrease Sensor is not detected before starting to operate.
PCB to insert is not found inner Machine.
1. Please put PCB on Sensor.
2. There is a possibility that PCB drops. Please check out Conveyor width.
42a103 Detect Suttle Conveyor Sensor in Input side
Stop Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42a104 Detect Suttle Conveyor Sensor in Input side
Stop Sensor is not detected before starting to operate.
PCB to insert is not found inner Machine.
1. Please conrm whether PCB is detected by Sensor or not.
2. There is a possibility that PCB drops. Please check out Conveyor width.
3.3 Conveyor
4OM-1840
3-3-491604-001
Error ID Error Name, Description, Cause, and Remedy
42a105 Detect Suttle Conveyor Sensor in Input side
PCB is detected from Decrease Sensor after nishing completely.
Please remove PCB from Shuttle Conveyor.
42a106 Detect Suttle Conveyor Sensor in Input side
PCB is not detected from Decrease Sensor after nishing completely.
Please conrm whether PCB is detected properly. And conrm whether Sensor
did not break down.
42a107 Detect Suttle Conveyor Sensor in Input side
PCB is detected from Stop Sensor after nishing completely.
Please remove PCB from Shuttle Conveyor.
42a108 Detect Suttle Conveyor Sensor in Input side
PCB is not detected from Stop Sensor after nishing completely.
Please conrm whether PCB is detected properly. And conrm whether Sensor
did not break down.
42a109 Detect Suttle Conveyor Sensor in Input side
PCB is detected from Shuttle Conveyor.
Please remove PCB from Conveyor.
42a10a Detect Suttle Conveyor Sensor in Input side
PCB is not detected from Shuttle Conveyor.
Please conrm whether PCB is detected properly. And conrm whether Sensor
did not break down.
42a10b Detect Suttle Conveyor Sensor in Input side
PCB has not got to shuttle Conveyor from Input Machine.
PCB from Input Machine is not transferred.
Please conrm whether PCB on the conveyor for Input machine is caught
42a10c Detect Suttle Conveyor Sensor in Input side
PCB is still on Shuttle conveyor.
To insert into inner Machine is not completed. Please check PCB position.
42a10d Detect Suttle Conveyor Sensor in Input side
PCB on Shuttle conveyor is gone.
It is possible to operate continuously.
Please conrm whether PCB went o its position if PCB is not removed on
purpose.
42a10e Detect Suttle Conveyor Sensor in Input side
PCB on Shuttle conveyor is changed.
PCB is inserted while not possible to be inserted. Please remove inserted PCB.
42a10f Detect Suttle Conveyor Sensor in Input side
The Sensor of Shuttle Conveyor is detected from both sides.
There is a possibility that two pieces of PCB are inserted. Please remove an
uncertain PCB. Please setup Timing to transfer PCB from Input machine.
3.3 Conveyor
4OM-1840
3-3-501604-001
Error ID Error Name, Description, Cause, and Remedy
42a201 Time-out of Shuttle Conveyor in Input side
Time-out is occurred during insert mode from Input Machine.
There is a possibility that PCB is stopped on conveyor.
1. Please conrm PCB position.
2. Please conrm whether Conveyor Width is t.
3. Please setup Input Conveyor Timer Value of System settings, and adjust
insert time.
42a202 Time-out of Shuttle Conveyor in Input side
Time-out is occurred during insert mode for Inner Machine.
PCB is stopped on Conveyor. Please conrm PCB Position.
1. Please conrm whether Transit Position from shuttle Conveyor is proper.
2. Please conrm whether Conveyor Width is t.
42a203 Time-out of Shuttle Conveyor in Input side
Time-out is occurred while Delivery Position from Input Machine is being moved.
Please conrm whether there is no error in Unit, no interference or not.
42a204 Time-out of Shuttle Conveyor in Input side
Time-out is occurred while Transfer position is being moved to Inner Machine.
Please conrm whether there is no error in Unit, no interference or not.
42a301 Shutter Conveyor Error in Input side
Error is made while Shuttle Conveyor is working.
-----
42b101 Shutter Conveyor Error in Output side
Decrease Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42b102 Shutter Conveyor Error in Output side
Decrease Sensor is not detected before starting to operate.
PCB to output is not found.
1. Please conrm whether PCB is detected by Sensor.
2. There is a possibility that PCB is dropping. Please conrm whether Conveyor
Width is t or not.
42b103 Shutter Conveyor Error in Output side
Stop Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42b104 Shutter Conveyor Error in Output side
Stop Sensor is not detected before starting to operate.
PCB to output is not found.
1. Please conrm whether PCB is detected by Sensor.
2. There is a possibility that PCB is dropping.
Please conrm whether Conveyor Width is t or not.
42b105 Shutter Conveyor Error in Output side
PCB is detected from Decrease Sensor after nishing completely.
Please remove PCB from Shuttle Conveyor.