Error ID Error Name, Description, Cause, and Remedy 42b106 Shutter Conveyor Error in Output side PCB is not detected from Decrease Sensor after nishing completely . Please conrm whether PCB is detected properly . And c…

Error ID Error Name, Description, Cause, and Remedy
42a201 Time-out of Shuttle Conveyor in Input side
Time-out is occurred during insert mode from Input Machine.
There is a possibility that PCB is stopped on conveyor.
1. Please conrm PCB position.
2. Please conrm whether Conveyor Width is t.
3. Please setup Input Conveyor Timer Value of System settings, and adjust
insert time.
42a202 Time-out of Shuttle Conveyor in Input side
Time-out is occurred during insert mode for Inner Machine.
PCB is stopped on Conveyor. Please conrm PCB Position.
1. Please conrm whether Transit Position from shuttle Conveyor is proper.
2. Please conrm whether Conveyor Width is t.
42a203 Time-out of Shuttle Conveyor in Input side
Time-out is occurred while Delivery Position from Input Machine is being moved.
Please conrm whether there is no error in Unit, no interference or not.
42a204 Time-out of Shuttle Conveyor in Input side
Time-out is occurred while Transfer position is being moved to Inner Machine.
Please conrm whether there is no error in Unit, no interference or not.
42a301 Shutter Conveyor Error in Input side
Error is made while Shuttle Conveyor is working.
-----
42b101 Shutter Conveyor Error in Output side
Decrease Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42b102 Shutter Conveyor Error in Output side
Decrease Sensor is not detected before starting to operate.
PCB to output is not found.
1. Please conrm whether PCB is detected by Sensor.
2. There is a possibility that PCB is dropping. Please conrm whether Conveyor
Width is t or not.
42b103 Shutter Conveyor Error in Output side
Stop Sensor is detected before starting to operate.
Please remove PCB from Shuttle Conveyor.
42b104 Shutter Conveyor Error in Output side
Stop Sensor is not detected before starting to operate.
PCB to output is not found.
1. Please conrm whether PCB is detected by Sensor.
2. There is a possibility that PCB is dropping.
Please conrm whether Conveyor Width is t or not.
42b105 Shutter Conveyor Error in Output side
PCB is detected from Decrease Sensor after nishing completely.
Please remove PCB from Shuttle Conveyor.
3.3 Conveyor
4OM-1840
3-3-511604-001

Error ID Error Name, Description, Cause, and Remedy
42b106 Shutter Conveyor Error in Output side
PCB is not detected from Decrease Sensor after nishing completely.
Please conrm whether PCB is detected properly. And conrm whether Sensor
did not break down.
42b107 Shutter Conveyor Error in Output side
PCB is detected from Stop Sensor after nishing completely.
Please remove PCB from Shuttle Conveyor.
42b108 Shutter Conveyor Error in Output side
PCB is not detected from Stop Sensor after nishing completely.
Please conrm whether PCB is detected properly. And conrm whether Sensor
did not break down.
42b109 Shutter Conveyor Error in Output side
PCB is detected from Shuttle Conveyor.
Please remove PCB from Conveyor.
42b10a Shutter Conveyor Error in Output side
PCB is not detected from Shuttle Conveyor.
Please conrm whether PCB is detected properly. And conrm whether Sensor
did not break down.
42b10b Shutter Conveyor Error in Output side
PCB has not got to shuttle Conveyor from Inner Machine.
PCB from Input Machine is not transferred.
Please conrm whether PCB on the conveyor for Input machine is caught
42b10c Shutter Conveyor Error in Output side
PCB is still on Shuttle Conveyor.
Output for Output Machine has not completed.
Please conrm PCB position.
42b10d Shutter Conveyor Error in Output side
PCB on Shuttle Conveyor is gone.
It is possible to operate continuously.
Please conrm whether PCB went o its position if PCB is not removed on
purpose.
42b10e Shutter Conveyor Error in Output side
PCB on Shuttle Conveyor is changed.
PCB is inserted while not possible to be inserted. Please remove inserted PCB.
42b10f Shutter Conveyor Error in Output side
The Sensor of Shuttle Conveyor is detected from both sides.
There is a possibility that two pieces of PCB are inserted. Please remove an
uncertain PCB.
42b201 Time-out of Shuttle Conveyor in Output side
Time-out is occurred during insert mode from inner Machine.
There is a possibility that PCB is stopped on conveyor.
1. Please conrm PCB position.
2. Please conrm whether Conveyor Width is t.
3. Please setup Input Conveyor Timer Value of System settings, and adjust
insert time.
3.3 Conveyor
4OM-1840
3-3-521604-001

Error ID Error Name, Description, Cause, and Remedy
42b202 Time-out of Shuttle Conveyor in Output side
Time-out is occurred during Output Mode for Output Machine.
PCB is stopped between Conveyors. Check out PCB position.
1. Please conrm whether Transit position from shuttle conveyor is proper.
2. Please conrm whether Conveyor Width is t.
42b203 Time-out of Shuttle Conveyor in Output side
Time-out is occurred while Transfer position from Inner Machine is being moved.
Please conrm whether there is no error in Unit, no interference or not.
42b204 Time-out of Shuttle Conveyor in Output side
Time-out is occurred while Delivery Position is being moved to Output Machine.
Please conrm whether there is no error in Unit, no interference or not.
42b301 Shuttle Conveyor Error in Output side.
Error is made while Shuttle Conveyor is working.
-----
42b401 Transfer check
PCB is detected on the conveyor. Please remove it.
-----
42b501 Transfer check
Going down in PCB stopper(L) was not completed within the predetermined time.
-----
42b502 Transfer check
Going down in PCB stopper(R) was not completed within the predetermined time.
-----
42b503 Transfer check
Going down in PCB stopper(AL) was not completed within the predetermined
time.
-----
42b504 Transfer check
Going down in PCB stopper(AR) was not completed within the predetermined
time.
-----
42b505 Transfer check
Going down in PCB stopper(BL) was not completed within the predetermined
time.
-----
42b506 Transfer check
Going down in PCB stopper(BR) was not completed within the predetermined
time.
-----
42b601 Transfer check
Going down in the backup base(L) was not completed within the predetermined
time.
-----