Error ID Error Name, Description, Cause, and Remedy 490731 Nozzle set up Failed in starting XY -axis. ----- 490732 Nozzle set up T ime-out of XY -axis ----- 490733 Nozzle set up Motor Error of XY -axis ----- 490734 Nozzl…

Error ID Error Name, Description, Cause, and Remedy
49070c Nozzle set up
Nozzle level teach error Detection.
Please execute the nozzle level teaching again on the nozzle level teach screen,
and conrm there is no unexpected value.
49070d Nozzle set up
It failed in the nozzle placement check.
Conrm the recognition image and select the nozzle existence.
Please select a recognition image and choose the existence of a nozzle.
49070e Nozzle set up
The remains nozzle was detected on the head. The nozzle cannot be set to this
position.
Please conrm the nozzle has not adhered to the position.
Moreover, please clean the linear measure when not adhering.
49070f Nozzle set up
Abnormal nozzle level detected. Possibilities are the nozzle was not fully inserted
in the head, or linear measure saw dust or scratch.
Please conrm whether the nozzle has adhered to the position.
490710 Nozzle set up
The receipt nozzle was undetectable on the head.
Please conrm whether the nozzle has adhered to the position.
490711 Nozzle set up
The remains nozzle was detected on the head.
Please conrm the nozzle has not adhered to the position.
Moreover, please clean the linear measure when not adhering.
490712 Nozzle set up
The linear measure error occurred in the head nozzle existence check.
Please conrm the nozzle arrangement, and execute the level teaching.
490713 Nozzle set up
The nozzle exchange sequence error occurred.
Please conrm the nozzle placement.
490716 Nozzle set up
Time-out of close nozzle stocker operation.
Nozzle stocker was opened for safety. Please conrm whether there is no rise to
the surface the nozzle is not in opening and shutting caught state.
490722 Nozzle set up
An error occurred with the nozzle existence check in the stocker before the nozzle
is stored.
-----
490723 Nozzle set up
It failed in the nozzle storage check.
Conrm the recognition image and select the nozzle existence.
-----
490730 Nozzle set up
Error in calculating recognized position of Nozzle ID.(XY-axis)
-----
3.6 Automatic Adjustment
4OM-1840
3-3-591604-001

Error ID Error Name, Description, Cause, and Remedy
490731 Nozzle set up
Failed in starting XY-axis.
-----
490732 Nozzle set up
Time-out of XY-axis
-----
490733 Nozzle set up
Motor Error of XY-axis
-----
490734 Nozzle set up
Error in Light on of P.C.B. recognition camera.
-----
490735 Nozzle set up
Error in capturing a image of P.C.B. recognition camera.
-----
490736 Nozzle set up
Error in recognizing Nozzle ID
-----
490737 Nozzle set up
Error in Light O of P.C.B. recognition camera.
-----
490738 Nozzle set up
Error in calculating Nozzle check position internal stocker.(XY-axis)
-----
490739 Nozzle set up
Error in recognizing Nozzle existence.
-----
49073A Nozzle set up
Can not recognize Nozzle ID
Please conrm the direction of Nozzle and the existence of Marking, the dirt
inside Nozzle stocker.
49073B Nozzle set up
Nozzle set in Nozzle Stocker and Nozzle data is not Identical.
Please conrm Nozzle and Nozzle data of the machine inside nozzle stocker.
49073C Nozzle set up
Error in nozzle exchange
-----
49073D Nozzle set up
Error in recognition sequence of Nozzle ID.
49073E Nozzle set up
Necessary Stocker Area for recognition Nozzle ID is skipped.
Clear the skip set of nozzle stocker.
3.6 Automatic Adjustment
4OM-1840
3-3-601604-001

Error ID Error Name, Description, Cause, and Remedy
49073F Nozzle set up
Time-out of Nozzle type data received.
-----
490740 Nozzle set up
Error of Nozzle type data received.
-----
490741 Nozzle set up
Error in updating Nozzle data.
-----
490742 Nozzle set up
Failed in start-up Z-axis
-----
490743 Nozzle set up
Time-out of start-up Head
-----
490744 Nozzle set up
Time-out of head
-----
490745 Nozzle set up
Error in calculating Noz exchanging position in L-axis
-----
490746 Nozzle set up
Failed in start-up L-axis
-----
490747 Nozzle set up
Time-out of start-up L-axis
-----
490748 Nozzle set up
Time-out of L-axis
-----
490749 Nozzle set up
Error in calculating Noz exchanging position in XY-axis
-----
49074A Nozzle set up
Error in calculating Noz exchanging position in L-axis.
-----
49074B Nozzle set up
Failed in getting arrangement data of Nozzle Stocker
-----
49074C Nozzle set up
Nozzle is found in Stocker, but Disagreement ID or ID recog failed.
Please conrm the type and direction of Noz inside Stocker.
Check the existence of the dirt or aw if there is no problem.
3.6 Automatic Adjustment
4OM-1840