Error ID Error Name, Description, Cause, and Remedy 490795 Nozzle set up Error in the nozzle stocker mark recog. There is a possibility that the stocker type is wrong. Please conrm that the set stocker in the unit repla…

100%1 / 315
Error ID Error Name, Description, Cause, and Remedy
490787 Nozzle set up
Error in the result of Linear Measure detect
-----
490788 Nozzle set up
Time-out of starting linear Measure detect (Noz diameter Recog)
-----
490789 Nozzle set up
Time-out of reading out the result of Linear Measure detect (Noz diameter Recog)
-----
49078A Nozzle set up
Error in the result of Linear Measure detect (Noz diameter Recog)
-----
49078B Nozzle set up
Failed in getting Noz type Data.
-----
49078C Nozzle set up
Exchanging Noz has not started within predetermined time
-----
49078D Nozzle set up
Exchanging Noz has not nished within predetermined time
-----
49078E Nozzle set up
Error in setting Drive Wave of HL-axis
-----
49078F Nozzle set up
Error in setting Drive Wave of NL-axis
-----
490790 Nozzle set up
Error in setting Drive Wave of L-axis
-----
490791 Nozzle set up
Error in coordinate calculation of shifting the Origin
-----
490792 Nozzle set up
Error in setting Sequence Data of HL-axis
-----
490793 Nozzle set up
Error in HL-axis operating
-----
490794 Nozzle set up
Error in L-axis operating
-----
3.6 Automatic Adjustment
4OM-1840
3-3-661604-001
Error ID Error Name, Description, Cause, and Remedy
490795 Nozzle set up
Error in the nozzle stocker mark recog. There is a possibility that the stocker type
is wrong.
Please conrm that the set stocker in the unit replace screen is the same as the
stocker type of the device. Please clean it up if there is no problem.
490796 Nozzle set up
It is impossible to place a nozzle whose end type is set besides [standard]
adjacent to a head.
-----
490797 Nozzle set up
It stopped by nozzle interference check.
Perform zeroing.
490798 Nozzle set up
Error in communication with recognition.
-----
490799 Nozzle set up
Time-out of communication with recognition.
-----
49079a Nozzle set up
Error in capturing a image with component recognizing camera.
-----
49079b Nozzle set up
To capture a image with component recognizing camera is not complete with the
predetermined time.
-----
49079c Nozzle set up
Error in recognition of nozzle position.
-----
49079d Nozzle set up
Time-out of recognition of nozzle position.
-----
49079e Nozzle set up
Failed in nozzle position teaching. Please conrm Nozzle ID, and then replace a
nozzle.
-----
49079f Nozzle set up
To set nozzle position data failed.
-----
4907A0 Nozzle set up
The nozzle stocker which is not for replace exists on input position.
Please perform all zeroing.
490801 Program -change linked operation
Program-change linked operation has not nished within appointed time.
-----
3.6 Automatic Adjustment
4OM-1840
3-3-671604-001
Error ID Error Name, Description, Cause, and Remedy
496001 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W1-axis operating.
Please remove the Backup Pin\Jig from Backup Base. Or, conrm whether
Sensor has error or not.
496002 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W2-axis operating.
Please remove the Backup Pin\Jig from Backup Base. Or, conrm whether
Sensor has error or not.
496003 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W3-axis operating
Please remove the Backup Pin\Jig from Backup Base. Or, conrm whether
Sensor has error or not.
496101 Conveyor Width W1 Error
Drive Alarm during Conveyor Width W1 axial operation.
Conrm reset Method of detailed Sub-system error counts of Alarm.
496102 Conveyor Width W1 Error
Conveyor Width W1-axis could not start
A state in which the operating command is not normally accepted.
1. Conrm connection to communication cable.
2. Conrm Power supply(24V).
3. Conrm the communication setting of PCI board.
4. Conrm the address of driver and communication rate setting.
496110 Conveyor Width W1 Error
System setup of Conveyor Width W1 is not completed.
Driver has not completed the parameter setup yet. It is a situation in which a
correct setup has not been received by Communication Error.
Check the Communication Mode, wiring, Power supply of Driver.
496111 Conveyor Width W1 Error
Zeroing Error in Conveyor Width W1
LS, discontinuous zeroing movement, was detected.
Check out the dirt, error of sensor and error in Motor body etc.
496112 Conveyor Width W1 Error
Out-of-Control in Conveyor Width W1
Motor Out-of-Control which is over the width of Out-of-Control detecting occurred.
Please execute all zeroing again, and the restart production.
Please set motor speed slow if it happens frequently. Also, in a case of structure
motor Error.
496113 Conveyor Width W1 Error
Error in Motor Power voltage of Conveyor Width W1
Motor power voltage dropped. Check out the Power supply line(48V Line)
496114 Conveyor Width W1 Error
STP input in Conveyor Width W1 was detected
STP input is detected. The function to stop motor by Hard signal.
3.6 Automatic Adjustment
4OM-1840