Error ID Error Name, Description, Cause, and Remedy 4b031B Feeder Base Positioning dropping prevention stopper(Block1) cannot lock. Please conrm the state of Feeder base and detect sensor of positioning drop prevention …

100%1 / 315
Error ID Error Name, Description, Cause, and Remedy
4b0308 Feeder Base
The connector (Block2) for the feeder base worked o. Do not remove the
connector during feeder base ascent.[B0916]
Connect the connector (Block2) for the feeder base to the machine main body.
4b0310 Feeder Base
The power was not turned on, or emergency stop was detected.
Please turn on the machine after conrm that Emergency Stop button is not
pressed.
4b0311 Feeder Base
Feeder Cart could not be detected.
Please execute operation again after setting Feeder Cart in predetermined place.
Please conrm whether it set in if the set is already done well.
4b0312 Feeder Base
Connector of Feeder Cart is not connected
Please execute operation again after connecting connector of Feeder Cutter.
4b0313 Feeder Base
NL-axis interlock was detected
Please execute zeroing when NL-axis is fallen.
4b0314 Feeder Base
Error in Feeder Base movement
----
4b0315 Feeder Base
Time-out in Clamp Movement of Elevator Unit
----
4b0316 Feeder Base
Time-out in Unclamp Movement of Elevator Unit
----
4b0317 Feeder Base
Illegal current position of Feeder base (Block1)
Please conrm Feeder base, and the sensor of Cylinder Upper limit
detection[B0614], Cylinder Lower limit detection[B0615].
4b0318 Feeder Base
Illegal current position of Feeder base (Block2)
Please conrm Feeder base, and the sensor of Cylinder Upper limit
detection[B0614], Cylinder Lower limit detection[B0615].
4b0319 Feeder Base
Positioning dropping prevention stopper(Block1) cannot cancel lock.
Please conrm the state of Feeder base and detect sensor of positioning drop
prevention lock[B0912][B0913]
4b031A Feeder Base
Positioning dropping prevention stopper(Block2) cannot cancel lock.
Please conrm the state of Feeder base and detect sensor of positioning drop
prevention lock[B0612][B0613]
3.8 Others
4OM-1840
3-3-871604-001
Error ID Error Name, Description, Cause, and Remedy
4b031B Feeder Base
Positioning dropping prevention stopper(Block1) cannot lock.
Please conrm the state of Feeder base and detect sensor of positioning drop
prevention lock[B0912][B0913]
4b031C Feeder Base
Positioning dropping prevention stopper(Block2) cannot lock.
Please conrm the state of Feeder base and detect sensor of positioning drop
prevention lock[B0612][B0613]
4b031D Feeder Base
Cart rising stopped(Block1).
Cannot release the safety cover for the cart in the opposite side is in process.
The process stopped because there is a possibility that something is placed
between Cart and the safety cover.
-----
4b031E Feeder Base
Cart rising stopped(Block2).
Cannot release the safety cover for the cart in the opposite side is in process.
The process is stopped because there is a possibility that something is placed
between Cart and the safety cover.
-----
4b031F Feeder Base
Failed that Automatic safety cover opening starts up. The process is stopped
because there is a possibility that something is placed between Cart and the
safety cover.
-----
4b0320 Feeder Base
Automatic safety cover opening is not completed in predetermined time. The
process is stopped because there is a possibility that something is placed
between cart and the safety cover.
-----
4b0321 Feeder Base
Failed in Automatic safety cover opening (Release Lock).
The process is stopped because there is a possibility that something is placed
between cart and the safety cover.
-----
4b0322 Feeder Base
Cannot distinguish a cart(Block1). Please operate it again.
-----
4b0323 Feeder Base
Cannot distinguish a cart(Block2). Please operate it again.
-----
4b0501 Manual alignment Error
Operation was not completed within predetermined time.
-----
3.8 Others
4OM-1840
3-3-881604-001
Error ID Error Name, Description, Cause, and Remedy
4b050f Manual alignment Error
Error was detected during operation.
-----
4b0701 Connection Error.
Failed in communications with the Control CPU.
-----
4b0702 Connection Error.
Failed in communications with the Recog. CPU.
-----
4b0801 Linear measure operation is abnormal.
Linear measure was found abnormality while measuring.
There is a possibility of Light Emitter and Receiver broken. Please conrm Error
from Log Request Screen(Unit adjustment -> Linear measure Sensor Screen)
4b0802 Linear measure operation error
The measurement by the linear measure sensor was not completed on time.
Communication connector of Linear measure Sensor P.C.B is taken o. Please
conrm whether the items of LS-RLS-S(Device Check -> List) is Yellow. HLS
communication cable could not be connected and such like things.
4b0803 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
Light Emitter and Receiver could have aw and soil. Please clean it up. Please
press [Operation] on the screen(Unit adjustment -> Linear measure Sensor ->
Detection test Screen) and conrm whether there is an error
4b0804 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
There is a possibility of Line Sensor P.C.B. broken
4b0805 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
A small light quantity of Light Emitter. Please exchange Light Emitter.
4b0806 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
There is a possibility of Line Sensor P.C.B. broken. Either, Please update Version
on the screen(Unit adjustment -> Linear measure Sensor -> Correct data read
Screen)
4b0807 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
Please conrm Error from Log Request Screen(Unit adjustment -> Linear
measure Sensor Screen). Either, please conrm whether the items of LS-RLS-
S(Device Check -> List) is Yellow.
HLS communication cable could not be connected and such like things.
3.8 Others
4OM-1840