4M184002w_F8S - 第252页
Error ID Error Name, Description, Cause, and Remedy 4b2004 P .C.B Height Measurement The abnormality number of times of measured value was beyond a set point. ----- 4b2005 P .C.B Height Measurement A measurement result i…

Error ID Error Name, Description, Cause, and Remedy
4b0808 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
Please conrm Error from Log Request Screen(Unit adjustment -> Linear
measure Sensor Screen). Either, please conrm whether the items of LS-RLS-
S(Device Check -> List) is Yellow.
HLS communication cable could not be connected and such like things.
4b0809 Linear measure operation error
There is a problem in the linear measure Sensor.(Strobe Signal did not turn o
within predetermined time.)
Please conrm Error from Log Request Screen(Unit adjustment -> Linear
measure Sensor Screen). Either, please conrm whether the items of LS-RLS-
S(Device Check -> List) is Yellow.
HLS communication cable could not be connected and such like things.
4b0c01 Nozzle Conrmation Error before pick up comp (Detect After Placement)
Because a component was found on a nozzle, it stopped after disposal.
The result could have some problems.
Please check placement state on placement step recovery screen.
4b0c02 Nozzle Conrmation Error before pick up comp
The remains component was found on a nozzle during production.
Please conrm whether there is an error in the P.C.B.
4b0c03 Nozzle Conrmation Error before pick up comp (Detect After Discard)
Because a component was found on a nozzle, it stopped after disposal.
Please conrm and clean up the nozzle if this error continues.
4b0e01 Splicing tape set error
The joint part of splicing tape is not correctly set. Please extract a feeder and
check whether the tape has separated from the guide.
-----
4b1201 Press in error / Insertion error
There is an error with the component pressed in or Insertion
Open safety cover and conrm the component on P.C.B. Please remove it or
revise it
4b19 Zeroing of single axis error
Timeout in zeroing of single axis.
-----
4b2001 P.C.B Height Measurement
Abnormal measured value was detected.
Check the measurement position.
4b2002 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2003 P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
Running is stopped.
-----
3.8 Others
4OM-1840
3-3-901604-001

Error ID Error Name, Description, Cause, and Remedy
4b2004 P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
-----
4b2005 P.C.B Height Measurement
A measurement result is abnormal(measure in arbitrary position)
Check the measurement position.
4b2006 P.C.B Height Measurement
Surpass a measurement range. (+ direction)
-----
4b2007 P.C.B Height Measurement
Surpass a measurement range. (- direction)
-----
4b2008 P.C.B Height Measurement
Detected a curve more than permission values. (+ direction)
-----
4b2009 P.C.B Height Measurement
Detected a curve more than permission values. (- direction)
-----
4b200a P.C.B Height Measurement
Error of the result measured by a master jig (height)
Check if the master jig (height) has some dirt and foreign particles.
4b200b P.C.B Height Measurement
Failed in wearing height revision.
-----
4b200c P.C.B Height Measurement
An abnormal measurement was detected by the multipoint measurement.
Check the measurement position.
4b200d P.C.B Height Measurement
Recovery by the multipoint measurement failed because the measurement result
was insucient.
Check the measurement position.
4b2011 P.C.B Height Measurement
Measurement time-out
-----
4b2081 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2082 P.C.B Height Measurement
Failed in wearing height revision.
-----
4b2083 P.C.B Height Measurement
Measurement time-out
-----
3.8 Others
4OM-1840
3-3-911604-001

Error ID Error Name, Description, Cause, and Remedy
4b2084 P.C.B Height Measurement
The coordinate where the height measurement was impossible was appointed.
Please appoint a coordinate in a measurable range.
4b2101 SSC network abnormal
There is abnormal in SSC network.
Please conrm the cable of SSC network.
4b2102 SSC network abnormal
There is a problem in connection to Servo Amplier(XY).
(1) Shut down the machine and check the connection between the position board
and amplier.
(2) Check whether or not the servo ampliers are damaged.
4b2103 SSC network abnormal
There is a problem in connection to Servo Amplier(Head).
(1) Shut down the machine and check the connection between the position board
and amplier.
(2) Check whether or not the servo ampliers are damaged.
4b2301 Feeder (Servo Error)
Alarm Code:A0 - Internal Parameter Error (Breakdown of Control P.C.B.)
Please replace the feeder. (Do not disconnect the feeder in powering on,
otherwise it may cause the inside data broken.)
4b2302 Feeder (Servo Error)
Alarm Code:A1 - Over Current Error (Foreign substances in the tape feeding drive
section)
Conrm whether or not the tape is being jammed on the path./ Conrm the reel to
operate smoothly./ Conrm whether or not some components and dust are being
caught in the sprocket./ Conrm whether or not some components and dust are
being caught in the tape feeding gear.
4b2303 Feeder (Servo Error)
Alarm Code:A2 - Others
-----
4b2304 Feeder (Servo Error)
Alarm Code:A3 - Others
-----
4b2305 Feeder (Servo Error)
Alarm Code:A4 - Main Circuit Power Supply Error (Please check the power supply
voltage.) (G04)
Please check the power supply voltage.
4b2306 Feeder (Servo Error)
Alarm Code:A5 - Fault Speed Error (Tape catching)
Conrm whether or not the tape is being jammed on the path.
Conrm the reel to operate smoothly.
Conrm whether or not some components and dust are being caught in the
sprocket.
Conrm whether or not some components and dust are being caught in the tape
feeding gear.
3.8 Others
4OM-1840
3-3-921604-001