4M184002w_F8S - 第267页
Error ID Error Name, Description, Cause, and Remedy 4b7201 BCD PP Change error Disconnected server for BCD PP change reference folder . Please checking connection status. ----- 4b7202 BCD PP Change error Could not output…

Error ID Error Name, Description, Cause, and Remedy
4b5801 Joint detect
A joint is detected.
Please perform consistency check.
4b5901 LISA Communication error
LISA communication has errors.
Please check the followings, PC condition, Hub condition and connection
condition to LAN cable for LISA.
4b5a01 Warning about Maintenance
The total number of the feeder shot exceeded the setting value. It is time to
perform the feeder maintenance.
-----
4b5a02 Warning about Maintenance
The feeder adsorption rate decreased and exceeded the previous notice setting
number. It is time to perform the feeder maintenance.
-----
4b6001 Time Synchronization error
The time dierence with the server device is 24 hours and more. Time
synchronization has been stopped.
There is a possibility that the battery of CPU board was dead.
Please inspect the battery of CPU board.
Please check the system time.
4b6101 Bowl Feeder power shut-o
Main power breaker of bowl feeder(Block1) is shut o.
Please check the power breaker of bowl feeder(Block1).
4b6102 Bowl Feeder power shut-o
Main power breaker of bowl feeder(Block2) is shut o.
Please check the power breaker of bowl feeder(Block2).
4b6201 Feeder information output error
It is a folder to output loaded feeder information le.
The server of output folder is not connected. Please take out and take in a feeder
after checking connection status.
-----
4b6202 Feeder information output error
Could not output loaded feeder information le.
The server of output folder is not connected. Please take out and take in a feeder
after checking connection status.
-----
4b6203 Feeder information output error
Could not delete output loaded feeder information le.
The server of output folder is not connected. Please take out and take in a feeder
after checking connection status.
-----
3.8 Others
4OM-1840
3-3-1051604-001

Error ID Error Name, Description, Cause, and Remedy
4b7201 BCD PP Change error
Disconnected server for BCD PP change reference folder. Please checking
connection status.
-----
4b7202 BCD PP Change error
Could not output pattern program list le to server for BCD PP change reference
folder. Please checking connection status and le of shared folder.
-----
4b7203 BCD PP Change error
Could not delete pattern program list le on server for BCD PP change reference
folder. Please checking connection status and le of shared folder.
-----
4b7204 BCD PP Change error
The PP info le is not found. Please register the PP info le with the GCM server.
-----
4b7205 BCD PP Change error
The format is abnormal of the PP info le (Placement OK/NG data is abnormal).
-----
4b7206 BCD PP Change error
The format is abnormal of the PP info le (Placement pattern ID name is
abnormal).
-----
4b7207 BCD PP Change error
The format is abnormal of the PP info le (Placement OK/NG data:NG).
-----
T4C12
3.8 Others
4OM-1840
3-3-1061604-001

3.9 Handling Error
Error ID Error Name, Description, Cause, and Remedy
500101 Comp. Missing (Sensor)
Comp. Missing (Sensor)
There is a possibility that the picked comps. have fallen on the feeder and please
conrm it.
500301 Comp. Missing (Recog)
Comp. Missing (Recog)
There is a possibility that the picked comps. have fallen on the feeder and please
conrm it.
500401 Comp. Recog Error
Comp. Recog Error
-----
500501 Shortage of Component
Shortage of Component
-----
500502 Feeder Reload Stop
Feeder Reload Stop (Splicing)
-----
500c01 Comp. Vertical(Sensor)
Comp. Vertical(Sensor)
-----
500f01 Comp. Thickness(Sensor)
Comp. Thickness(Sensor)
-----
501001 Opt. Error(Feeder)
Feeder falls out
Feeder fell out during operation. Please check out it because there is a possibility
that Nozzle is damaged.
501101 Obverse/Reverse inspection error(Sensor)
Obverse/Reverse inspection error(Sensor)
-----
T4C13
3.9 Handling Error
4OM-1840
3-3-1071604-001