Error ID Error Name, Description, Cause, and Remedy 51 1220 Transfer Section's Preparation Error Upward movement on PCB Stopper(REV) is abnormal. There is a possibility that PCB stopper is broken or not Air in. 51 1…

Error ID Error Name, Description, Cause, and Remedy
511207 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(AL) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511208 Transfer Section's Preparation Error
Upward movement on PCB Stopper(AL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511209 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511210 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(AR) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511211 Transfer Section's Preparation Error
Upward movement on PCB Stopper(AR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511212 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511213 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(BL) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511214 Transfer Section's Preparation Error
Upward movement on PCB Stopper(BL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511215 Transfer Section's Preparation Error
Downward movement on PCB Stopper(BL) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511216 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(BR) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511217 Transfer Section's Preparation Error
Upward movement on PCB Stopper(BR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511218 Transfer Section's Preparation Error
Downward movement on PCB Stopper(BR) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511219 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(REV) are detected
simultaneously.
Please check out the wiring and adjust Limits.
3.10 Automatic Operation Error
4OM-1840
3-3-1101604-001

Error ID Error Name, Description, Cause, and Remedy
511220 Transfer Section's Preparation Error
Upward movement on PCB Stopper(REV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511221 Transfer Section's Preparation Error
Downward movement on PCB Stopper(REV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511222 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(AREV) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511223 Transfer Section's Preparation Error
Upward movement on PCB Stopper(AREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511224 Transfer Section's Preparation Error
Downward movement on PCB Stopper(AREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511225 Transfer Section's Preparation Error
Upward Limit and Downward Limit on PCB Stopper(BREV) are detected
simultaneously.
Please check out the wiring and adjust Limits.
511226 Transfer Section's Preparation Error
Upward movement on PCB Stopper(BREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511227 Transfer Section's Preparation Error
Downward movement on PCB Stopper(BREV) is abnormal.
There is a possibility that PCB stopper is broken or not Air in.
511301 Added squeeze error
Added squeeze is not completed.
Open the safety cover and check the placed components. Then, please remove
or revise them.
511401 Automatic correction of missed standard mark
Error in automatic correction of missed standard mark.
Please redo oset teaching of PCB mark position.
511402 Automatic correction of missed standard mark
Timeout of automatic correction of missed standard mark.
Please redo oset teaching of PCB mark position.
511403 Automatic correction of missed standard mark
Error in recognizing standard mark.
Please redo oset teaching of PCB mark position.
T4C14
3.10 Automatic Operation Error
4OM-1840
3-3-1111604-001

3.11 Test
Error ID Error Name, Description, Cause, and Remedy
610101 Opearation error has occurred.
-----
-----
T4C16
3.11 Test
4OM-1840
3-3-1121604-001