4M184002w_F8S - 第275页
Error ID Error Name, Description, Cause, and Remedy 700154 Barcode Detection PCB nishing position Setup in Pattern Program diers before and after Program Change. ----- T4C18 3.12 Barcode Detection 4OM-1840 3-3-1 14 160…

3.12 Barcode Detection
Error ID Error Name, Description, Cause, and Remedy
700101 Barcode Detection
The bar code data is not read.
-----
700102 Barcode Detection
The pattern program is not found.
-----
700111 Barcode Detection
Program -change was not able to executed.
-----
700112 Barcode Detection
Application error.
-----
700114 Barcode Detection
The product.operation was not able to begin.
-----
700115 Barcode Detection
Bar Code Program-change process cannot be excuted "PRODUCT.SCRN,"or
"COMP.RELD.SCRN."
-----
700118 Barcode Detection
Illegal bar code ID.
-----
700119 Barcode Detection
Bar code ID eective range is illegal.
-----
700120 Barcode Detection
Ptn.Prgm. specied by Crnt.Prgm. and barcode is dierent.
-----
700125 Barcode Detection
2D bar code mode of the pattern program is "Disable".
-----
700151 Barcode Detection
It is impossible to change Barcode on the Dual machine.
-----
700152 Barcode Detection
Current program is not set.
-----
700153 Barcode Detection
PCB nishing position of Pattern Program for Program Change is set except [Input]
and [Output].
-----
3.12 Barcode Detection
4OM-1840
3-3-1131604-001

Error ID Error Name, Description, Cause, and Remedy
700154 Barcode Detection
PCB nishing position Setup in Pattern Program diers before and after Program
Change.
-----
T4C18
3.12 Barcode Detection
4OM-1840
3-3-1141604-001

3.13 ACV
Error ID Error Name, Description, Cause, and Remedy
740305 ACV:Feeder Location Error
Feeder location error is found on tray (Block1).
Conrm the position of components, and then do registrating operation.
740306 ACV:Feeder Location Error
Feeder location error is found on tray (Block2).
Conrm the position of components, and then do registrating operation.
740501 ACV Time-out
Device(Block1) Time-out in receiving the result of ACV Check Error. Component
ID on the feeder is not same as one specied by current program.
-----
740502 ACV Time-out
Device(Block2) Time-out in receiving the result of ACV Check Error. Component
ID on the feeder is not same as one specied by current program.
-----
740605 ACV feeder check
Tray(Block1) parts empty.
Supply parts and register one.
-----
740606 ACV feeder check
Tray(Block2) parts empty.
Supply parts and register one.
-----
740701 ACV server timeout
ACV server process didn't respond in proper time.
-----
740702 ACV server timeout
-----
-----
740703 ACV server timeout
Error in an internal data ACV communication program. Please turn o a breaker.
-----
740704 ACV server timeout
Errors in the format of retrieval result of the ACV database.
-----
740705 ACV server timeout
Failed in the access to the ACV database.
-----
740706 ACV server timeout
The waiting time of the ACV database backup processing was exceeded.
-----
740707 ACV server timeout
There was no communication response from the ACV database.
-----
3.13 ACV
4OM-1840
3-3-1151604-001