4M184002w_F8S - 第288页
Recognition Error ID Description of Recognition Error 02200802 T otals of "the number of form" is not sucient. 02200803 No detection is set in all "Form Insp Condtn" text boxes. 02200804 "Direct…

Recognition Error ID Description of Recognition Error
02200768 "Missing Start Row or Col" in "Elctd Group 24" is large.
02200769 "Missing Start Row or Col" in "Elctd Group 25" is large.
0220076a "Missing Start Row or Col" in "Elctd Group 26" is large.
0220076b "Missing Start Row or Col" in "Elctd Group 27" is large.
0220076c "Missing Start Row or Col" in "Elctd Group 28" is large.
0220076d "Missing Start Row or Col" in "Elctd Group 29" is large.
0220076e "Missing Start Row or Col" in "Elctd Group 30" is large.
02200771 "Elctd # of Rows or # of Cols" in "Elctd Group 1" is not sucient.
02200772 "Elctd # of Rows or # of Cols" in "Elctd Group 2" is not sucient.
02200773 "Elctd # of Rows or # of Cols" in "Elctd Group 3" is not sucient.
02200774 "Elctd # of Rows or # of Cols" in "Elctd Group 4" is not sucient.
02200775 "Elctd # of Rows or # of Cols" in "Elctd Group 5" is not sucient.
02200776 "Elctd # of Rows or # of Cols" in "Elctd Group 6" is not sucient.
02200777 "Elctd # of Rows or # of Cols" in "Elctd Group 7" is not sucient.
02200778 "Elctd # of Rows or # of Cols" in "Elctd Group 8" is not sucient.
02200779 "Elctd # of Rows or # of Cols" in "Elctd Group 9" is not sucient.
0220077a "Elctd # of Rows or # of Cols" in "Elctd Group 10" is not sucient.
0220077b "Elctd # of Rows or # of Cols" in "Elctd Group 11" is not sucient.
0220077c "Elctd # of Rows or # of Cols" in "Elctd Group 12" is not sucient.
0220077d "Elctd # of Rows or # of Cols" in "Elctd Group 13" is not sucient.
0220077e "Elctd # of Rows or # of Cols" in "Elctd Group 14" is not sucient.
0220077f "Elctd # of Rows or # of Cols" in "Elctd Group 15" is not sucient.
02200780 "Elctd # of Rows or # of Cols" in "Elctd Group 16" is not sucient.
02200781 "Elctd # of Rows or # of Cols" in "Elctd Group 17" is not sucient.
02200782 "Elctd # of Rows or # of Cols" in "Elctd Group 18" is not sucient.
02200783 "Elctd # of Rows or # of Cols" in "Elctd Group 19" is not sucient.
02200784 "Elctd # of Rows or # of Cols" in "Elctd Group 20" is not sucient.
02200785 "Elctd # of Rows or # of Cols" in "Elctd Group 21" is not sucient.
02200786 "Elctd # of Rows or # of Cols" in "Elctd Group 22" is not sucient.
02200787 "Elctd # of Rows or # of Cols" in "Elctd Group 23" is not sucient.
02200788 "Elctd # of Rows or # of Cols" in "Elctd Group 24" is not sucient.
02200789 "Elctd # of Rows or # of Cols" in "Elctd Group 25" is not sucient.
0220078a "Elctd # of Rows or # of Cols" in "Elctd Group 26" is not sucient.
0220078b "Elctd # of Rows or # of Cols" in "Elctd Group 27" is not sucient.
0220078c "Elctd # of Rows or # of Cols" in "Elctd Group 28" is not sucient.
0220078d "Elctd # of Rows or # of Cols" in "Elctd Group 29" is not sucient.
0220078e "Elctd # of Rows or # of Cols" in "Elctd Group 30" is not sucient.
02200791 Electrode Shape = Proper recognition data corresponded to the rectangle was
not set.
02200792 Electrode Shape = Proper recognition level corresponded to the rectangle was
not set.
02200793 This algorithm cannot be applicable to the rectangle in the electrode shape.
02200794 the electrodes are not set as all of them have the same shape.
02200801 "# of Groups" (form data) is improper.
3. Recognition Error IDs and Remedial Procedures
4OM-1840
4-1-61604-001

Recognition Error ID Description of Recognition Error
02200802 Totals of "the number of form" is not sucient.
02200803 No detection is set in all "Form Insp Condtn" text boxes.
02200804 "Direction of shape" of the edge shape is all parallel.
02200805 "Width of shape" is small.
02200806 "Height of shape" is small.
02200807 "Shape pitch" is small.
02200808 The interval of shape is narrow.
02200809 There is a lot of "Number of shape".
0220080a The total of the edge shape is little.
0220080b The setting of the recognition level is improper otherwise, unnecessary shape
was registered.
02200851 "Graphic number of group" is small.
02200901 "Mold Size Tolerance X" is larger than "Mold Size X".
02200902 "Mold Size Tolerance Y" is larger than "Mold Size Y".
02200903 "Outward Length Tolerances" are larger than "Outward Length".
02200904 "Polarity Inspection Position" out of "Mold Size"
02200905 Selected algorithm is improper.
02200906 Failed in automatic selection of algorithm.
02200907 Dierent View in "View set" is set
02200908 "Range of both sides decision inspection" is small.
02200909 "Position of both sides decision inspection" is not within a size of a component.
0220090a [Pick-up pos. correction] is being set although the cmpnt size is large.
0220090b [Input direction] is set by 45(deg) although the cmpnt size is large.
0220090c [Pick-up angle] is being set although the cmpnt size is large.
0220090d Input direction is not the width's direction although the cmpnt size is large.
02200a01 The nozzle cannot be used because the method of illuminating is dierent from
lighting method of the component library.
02200a02 "Flux spread conrmation" can not be performed because "electrode width" is
small.
02200a03 Cannot do "Flux spread conrmation" because "Electrode space" is narrow.
02200b01 "Window Size" is smaller than "BarCode Size".
02200c01 It is o the subject of the division recognition processing(too large component
size)
02200c02 It is o the subject of the division recognition processing(decision inspection)
02200000 Others.
02300000 Recognition Communication Procedure Error.
02400001 An error occurred during data transfer between recognition and counter boards.
02400002 An error occurred during data transfer between recognition and lighting control
boards.
02400003 Lighting control board self-diagnostic abnormalities
02400004 Lighting control board self-diagnostic abnormalities
02400005 Lighting control board self-diagnostic abnormalities
02400101 The Comp. recognition lighting of beam 1 did not light.
02400102 The Comp. recognition lighting of beam 2 did not light.
3. Recognition Error IDs and Remedial Procedures
4OM-1840
4-1-71604-001

Recognition Error ID Description of Recognition Error
02400103 The Comp. recognition lighting of beam 3 did not light.
02400104 The Comp. recognition lighting of beam 4 did not light.
02400301 There is the dierence with settings for PEC Recognition Camera1.
02400302 There is the dierence with settings for PEC Recognition Camera2.
02400000 Others.
02900000 Others.
02900001 Image Acquiring in was interrupted.
02900002 The eye match was interrupted.
02900003 Failed in a division calculation of placement coordinate teaching.
02900101 Image data le can't be saved.
02900102 Image data le can't be saved.
02900103 Image data le can't be saved.
02900104 Image data le can't be saved.
02900105 Image data le can't be saved.
02900106 Data error.
02900107 Exception error.
02900108 There is no empty area enough for the disk.
02d00000 Error in Recognition internal.
02e00000 Error in Recognition internal.
12000000 Error in Recognition internal.
05000000 Others.
05000001 Component was not found.
05100001 Component was not detected.
05100101 The detection window of the length position of lead sequence can't be set up.
05100102 The length position of a lead sequence can't be detected.
05100103 Impossible to set the window for lead detection at the corner.
05100104 The lead edge of a corner can't be detected.
05100105 The lead of a corner can't be detected.(Cmpnt Angle inclined)
05100106 few lead numbers of the detected corner than the set-up.
05100107 The distance during the lead of the detected corner is poor.(Cmpnt Angle
inclined)
05100108 The angle during the lead of the detected corner is poor.
05100201 No Electrode(ball) Detected.
05100601 Shape (L type) cannot be detected.
05100602 Shape (U type) cannot be detected.
05100603 Shape (edge) cannot be detected.
05100604 Shape (rectangle) cannot be detected.
05100605 Shape (oval) cannot be detected.
05100000 Others.
05200101 More than two corners of a component are hidden by the protruded nozzle.
05200102 Corner not detected.
05200201 Some edges cannot be detected because they are hidden by the nozzle.
05200202 Edge not detected.
05200203 Some edges cannot be detected because they are hidden by the nozzle.
3. Recognition Error IDs and Remedial Procedures
4OM-1840
4-1-81604-001