4M184002w_F8S - 第75页
4OM-1840 1-3-2 1604-001 Bank Feeder Change Cart XY-Beam (X-Axis Beam) XY-Beam Section (Y-Axis Beam) Component Recognition Camera Placemant Head, PEC Recognition Section PCB Transfer Conveyor Unit Rejected Component Box N…

4OM-1840
1-3-11604-001
3. Maintenance Spots
3. Maintenance Spots
3.1 Whole View
Notice
Any operations with a cover(s) being removed are included.
After the maintenance work, be sure to attach the cover.
Feeder Cart Section
Air Source
Fans Section
Power Breaker
Fig. 4A3-1 Front Side of Machine
Reference
(a) Refer to "4." in "Chapter 1" and the subsequent items for the detailed
information on the spots of each section to be maintained and how to
maintain them.
(b) As for the options, refer to each instruction manual of the specially

4OM-1840
1-3-21604-001
Bank Feeder Change Cart
XY-Beam
(X-Axis Beam)
XY-Beam Section (Y-Axis Beam)
Component
Recognition Camera
Placemant Head,
PEC Recognition Section
PCB Transfer
Conveyor Unit
Rejected Component Box
Nozzle Stocker Section
Fig. 4A3-2
3.1 Whole View

4OM-1840
1-4-11604-001
4. Inspection, Cleaning, and Lubrication Spots
4. Inspection, Cleaning, and Lubrication Spots
The following describes about the maintenance tasks required for each individual
units.
Reference
Refer to "2. Maintenance Check List" in "Chapter 1" for the maintenance items
4.1 Air Source
Air Blowing Pressure
Every Day Inspection
Required Time: 1 minute
Main Air Pressure
Every Day Inspection
Required Time: 1 minute
Drain
Drain
Every Week Cleaning
Required Time: 5 minutes
Fig. 4A4-1