Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 164 If a fuse group is selected (here 24V ), a corresponding view is displaye d. Figure 9- 11 : Fuse group view The states of the assigned fuses…

100%1 / 290
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
163
In the CAP tab, data related to the Diagnosis Master is displayed.
The power supplies (SMPS) and fuses (24V, 27V etc.) can be selected to the right. The fuses are
grouped by their respective voltage.
Figure 9-9: Diagnosis Master dialog SMPS tab
In the SMPS tab (here: QT40.999), data related to the respective power supply is displayed. There
may be two tabs, one for each possibly existing power supply. If only one power supply exists, the
second tab is disabled.
Sensors related to the safety circuit of the machine are grouped in the CSS view (Contactor-based
Safety Switch-off) to the right.
Figure 9-10: CSS view
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
164
If a fuse group is selected (here 24V), a corresponding view is displayed.
Figure 9-11: Fuse group view
The states of the assigned fuses are displayed in the following colors:
Gray: switched off
Green: switched on
Red: faulty
One long name and one short name are displayed for each fuse. The short names are the same as
those in the figures of the real hardware that can be found in the Online help of the station
software.
Additionally, the number of voltage drops since the last reset is displayed. The counter for all
displayed fuses can be reset with the Reset voltage drop counter button.
9.19 WDTL Multiple Set-up Components in Barcode Controlled
Production with Synchronous Dual Lane Mode
Compatible mode: Not supported
The station software now supports multiple set-up components in barcode-controlled production
with synchronous dual lane mode. Multiple set-up components mean that the components are set-
up on more than one station.
In synchronous dual lane mode, each of the two boards gets the same unique ID for the SIPLACE
Pro job in the first station. This ID will be transferred by WDTL through the line.
If boards with the same ID are moved together into another station, the boards will be placed
together with the same SIPLACE Pro job. This is the usual case.
If boards with different IDs are moved together into another station, the boards will be separated
and separately placed in asynchronous mode.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
165
Prerequisites
All stations in the line must be equipped with the same station software (version 708.1 or
higher).
WDTL must be provided through the complete line. If a SIPLACE cluster is interrupted by a
device like an AOI system, WDTL is only possible via individual PCB barcodes.
9.20 "Feeding on Demand" Option for Tape Feeders
Compatible mode: Complete
As of this station software version, the Feeding on Demand option can be used for all tape
feeders. With this option it can be avoided that components remain in the tape without a cover foil
and fall out at a changeover.
The option is set in the SetupUnitTypes.xml configuration file and oriented either to the head cycle
or the board cycle dependent on the feeder type. For fast feeders like the 8 mm and 2x8 mm
X-feeders, the head cycle variant is used.
The board cycle variant can be enabled per station. Only one sequence for each feeder type can
be set and a mixture is not supported.
NOTICE
Components without a cover foil can possibly remain in the tape if a board is canceled,
i.e. if it has not been completely placed.
9.21 Configurable "Pickup Components during Measuring Fiducials"
Compatible mode: Not supported
Previously it was standard that the components were already picked up and measured while the
board entered the machine for a faster passing through. This practice was only suppressed if ink
spots had to be evaluated.
Now it can be configured in SIPLACE Pro if pre-pickup shall be performed always, never or
dependent of the recipe.
The option can only be overridden by correcting the configuration files of the station software
respectively. However, this should only be performed for test and integration purposes.