Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 222 After pressing the Start button the Exe cution page will be opene d. Figure 11 -8: Teach accel eration values – Execution The execution step…

100%1 / 290
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
221
11.5.4 Support to Find Best Acceleration
A new teaching function supports finding the highest acceleration or speed values for a component
shape. For this, the dialog for teaching component shapes has been enhanced by the new Teach
acceleration values menu entry under Actions as of the Machine service activity level. By
triggering this action, a Configuration page is displayed.
Figure 11-7: Teach acceleration values Configuration
Following decisions must be made:
Nozzle to be used
If the user wants to perform the teaching with another nozzle, the nozzle can be selected from
a list. Only available nozzles will be displayed.
Option for disabling the rejection of components
The default value is to reject the components automatically. But if the Components must be
removed manually option is set, the operator will be prompted to remove the component
manually from the placement head as soon as the check fails. The option is only available for
placement heads for which this is possible. Once set, the value is saved for the next run.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
222
After pressing the Start button the Execution page will be opened.
Figure 11-8: Teach acceleration values Execution
The execution steps are displayed together with the reference Vision image and the last Vision
image done by the camera. Additionally, the current acceleration values of the axes and the
measured deviations are displayed. If the operator must remove a component from the placement
head manually or if the component is lost, a hint will be displayed, and the operator must confirm
the action to continue.
If an error occurs during execution, the error causes are displayed on the last page in an error list.
Otherwise, the results are presented in a table with all the measured values of the deviations and
the recommended accelerations values.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
223
Figure 11-9: Teach acceleration values Results
The recommended values can be compared with the values of the programming system. Different
values are highlighted. Usually, the recommended values will be tested after measurement. For
this, the Test recommended acceleration values button is offered. If pressed, the teach dialog
will be closed and the test dialog opened.
If the acceleration value of an axis is not relevant for the measurement, an empty cell will be
displayed. The displayed axes depend on the used placement head. A line displaying the value of
the vacuum system will be displayed if a vacuum pump is used in the machine. Thus, the operator
can check that the acceleration values were determined while having a value like the one during
production.
The upload to SIPLACE Pro is not available until the recommended values have been tested.