Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 234 ● Display of overall machine refere nce run time The total execution hours of the Machine reference run will be di splayed under Maintenance…
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
233
12.5 Unique Machine Data for Quality Check
Compatible mode: Complete
Machine data may only be restored on the corresponding machine. Thus, the stored data contains
the machine ID which is compared to the machine's ID before restoring the machine data. Only
when the IDs match each other, the data can be used on the machine.
This way it can be prevented that wrong data is used by mistake (e.g. after changing the station
computer) and the machine might produce inaccurately using wrong calibration data.
12.6 Enhanced Machine Endurance Run
Compatible mode: Complete
The following changes and enhancements have been made for the machine endurance run:
● The machine endurance run has been moved from Manual Operations to the Maintenance
view.
● The machine endurance run has been enhanced by endurance run cycles for three new
subsystems:
– Feeder locking
– Nozzle changers
– Pin picker
The additional subsystems will be performed in each third endurance cycle.
The Feeder locking endurance run cycle will lock and unlock all feeders on all tables.
This endurance run will take place each third endurance run cycle, starting with the second
cycle.
If an error occurs, a warning is displayed but the entire endurance run will not stop. In further
cycles, the feeder endurance run will no longer be performed.
The Nozzle changer endurance run cycle will open and close each nozzle changer carrier one
after the other. This endurance run will take place each third endurance run cycle, starting with
the first cycle.
If an error occurs, a warning is displayed but the entire endurance run will not stop. In further
cycles, the nozzle changer endurance run will no longer be performed.
The Pin picker endurance run cycle will let a pin picker pick a pin from the calibration garage
of a calibrated magazine and place it back to the same position. Thus, the operator must
ensure that a pin is available there. This will be checked before the endurance run starts (after
magazine scanning). If this precondition is not fulfilled, the pin picker will be no part of the
endurance run.
This endurance run will take place each third endurance run cycle, starting with the third cycle.
If an error occurs, the entire endurance run will stop.
● An optional endurance run can be started before starting the calibration or after successful
calibration in the Automatic calibration view.
In both cases the Machine reference run is performed.
The duration of the endurance run before and after calibration can be configured
independently. The range of values of both input fields is: 0 - 100 hours.
Default for endurance run before calibration: 1 hour.
Default for endurance run after calibration: 100 hours.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
234
● Display of overall machine reference run time
The total execution hours of the Machine reference run will be displayed under Maintenance
– Machine endurance runs – Total duration of machine reference endurance runs [h].
The value of the counter is only visible at the SIPLACE service activity level.
12.7 Component Position Check
Compatible mode: Complete
A component (e.g. a SIM card holder) shall be placed on top of another component in the same
SIPLACE machine with the Twin Head. For some SIM card holders, the leads need to be placed
through holes inside the boards. Therefore, the machine must verify the following before a SIM
card holder is placed:
– Presence of the bottom component.
– Correct placement position of the bottom component regarding X-, Y-offset and angle within a
certain definable tolerance range.
The whole bottom component will be described as a local fiducial in SIPLACE Pro. The top
component (here = SIM card holder) related to the local fiducial will not be placed based on the
local fiducial position but on the programmed position. The SIPLACE Pro user must ensure that the
bottom component is placed before the SIM card holder by setting an appropriate precedence rule.
If the bottom component cannot be recognized, the fiducial (= bottom component) must be taught
at the station.
If the measurement exceeds the defined tolerance, the operator can select to skip the remaining
components of the panel to which the bottom component belongs or place the panel anyway.
Error Handling at the Station
The following error events may occur at the station after measurement:
1. No Vision measurement result available because:
– the bottom component is missing
– the bottom component is outside the search area
– the fiducial is incomplete
2. Measured bottom component position exceeds the tolerance.
In the first case, the operator will be prompted to teach the fiducial and repeat the measurement.
In the second case, a detailed error dialog displays the Vision image and the measured X, Y and
angle values of the bottom component. The current tolerance of the bottom component position is
displayed as well.
The operator can select between the following options:
► Skip placement of panel
i.e., skip placement of the remaining components of the panel to which the bottom component
belongs.
► Ignore result and continue with placement in panel
i.e., place the SIM card holder although the tolerance is exceeded.

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
235
12.8 Using Two Dip Modules for Dipping
Compatible mode: Complete
If two LDU dip modules are positioned on the same table and have the same type of flux medium
and same cavity depth, the station software uses both dip modules to dip components. The
components of one head-cycle are distributed on both dip modules.
12.9 Enhanced FCCS Tool
Compatible mode: Complete
The FCCS tool has been enhanced to support camera verification of camera types SST47 and
SST25 in combination with the CPP placement head.
12.10 Enhanced SIPLACE Vision Functionality
NOTICE
Detailed information on the SIPLACE Vision functions can be found in the online help of
the station software.
SIPLACE Vision has been enhanced as follows:
– The QR barcode type is supported. All QR barcodes of the 18004 ISO/IEC norm with format
Model 2 are supported.
Compatible mode: Compatible
– To avoid that an incorrect barcode is read for traceability purposes, the user can define
conditions for the barcode in the Vision system. If a barcode does not fulfill all conditions, the
Vision system looks for another barcode with valid conditions in the region of interest. The
conditions are saved in SIPLACE Pro.
Compatible mode: Hidden
– The Component Shape wizard supports teaching groups and regular grids of THT round pins
and THT square pins.
Compatible mode: Compatible
– The new camera types SST48 and SST49 are supported. Please also refer to section 12.13.
Compatible mode: Hidden
– Improved display of measuring steps on the GUI.
Compatible mode: Complete