SIPLACE Station Software 7xx to 714 介绍 - 第235页
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 235 12.8 Using Two Dip Modules for Dipping Compatible mode: Complete If two LDU dip modules ar e positioned on the same t able and have the same…
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
234
● Display of overall machine reference run time
The total execution hours of the Machine reference run will be displayed under Maintenance
– Machine endurance runs – Total duration of machine reference endurance runs [h].
The value of the counter is only visible at the SIPLACE service activity level.
12.7 Component Position Check
Compatible mode: Complete
A component (e.g. a SIM card holder) shall be placed on top of another component in the same
SIPLACE machine with the Twin Head. For some SIM card holders, the leads need to be placed
through holes inside the boards. Therefore, the machine must verify the following before a SIM
card holder is placed:
– Presence of the bottom component.
– Correct placement position of the bottom component regarding X-, Y-offset and angle within a
certain definable tolerance range.
The whole bottom component will be described as a local fiducial in SIPLACE Pro. The top
component (here = SIM card holder) related to the local fiducial will not be placed based on the
local fiducial position but on the programmed position. The SIPLACE Pro user must ensure that the
bottom component is placed before the SIM card holder by setting an appropriate precedence rule.
If the bottom component cannot be recognized, the fiducial (= bottom component) must be taught
at the station.
If the measurement exceeds the defined tolerance, the operator can select to skip the remaining
components of the panel to which the bottom component belongs or place the panel anyway.
Error Handling at the Station
The following error events may occur at the station after measurement:
1. No Vision measurement result available because:
– the bottom component is missing
– the bottom component is outside the search area
– the fiducial is incomplete
2. Measured bottom component position exceeds the tolerance.
In the first case, the operator will be prompted to teach the fiducial and repeat the measurement.
In the second case, a detailed error dialog displays the Vision image and the measured X, Y and
angle values of the bottom component. The current tolerance of the bottom component position is
displayed as well.
The operator can select between the following options:
► Skip placement of panel
i.e., skip placement of the remaining components of the panel to which the bottom component
belongs.
► Ignore result and continue with placement in panel
i.e., place the SIM card holder although the tolerance is exceeded.

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
235
12.8 Using Two Dip Modules for Dipping
Compatible mode: Complete
If two LDU dip modules are positioned on the same table and have the same type of flux medium
and same cavity depth, the station software uses both dip modules to dip components. The
components of one head-cycle are distributed on both dip modules.
12.9 Enhanced FCCS Tool
Compatible mode: Complete
The FCCS tool has been enhanced to support camera verification of camera types SST47 and
SST25 in combination with the CPP placement head.
12.10 Enhanced SIPLACE Vision Functionality
NOTICE
Detailed information on the SIPLACE Vision functions can be found in the online help of
the station software.
SIPLACE Vision has been enhanced as follows:
– The QR barcode type is supported. All QR barcodes of the 18004 ISO/IEC norm with format
Model 2 are supported.
Compatible mode: Compatible
– To avoid that an incorrect barcode is read for traceability purposes, the user can define
conditions for the barcode in the Vision system. If a barcode does not fulfill all conditions, the
Vision system looks for another barcode with valid conditions in the region of interest. The
conditions are saved in SIPLACE Pro.
Compatible mode: Hidden
– The Component Shape wizard supports teaching groups and regular grids of THT round pins
and THT square pins.
Compatible mode: Compatible
– The new camera types SST48 and SST49 are supported. Please also refer to section 12.13.
Compatible mode: Hidden
– Improved display of measuring steps on the GUI.
Compatible mode: Complete
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
236
Features (V711.1 (R18-1): Compatible Mode 710.3)
12.11 SIPLACE TX V2 – New Placement Machine
Compatible mode: Hidden
The new SIPLACE TX V2 placement machine supports placement on a dual conveyor system and
is available in three configurations: TX1 V2 (single gantry), TX2 V2 (dual gantry) and TX2i V2 (dual
gantry, inner table). The dual conveyor can be used as single conveyor in Flexible Dual Lane mode
when boards with at width > 260 mm are placed. In this case, the Flexible Dual Lane – Machine
Connection Bound license is required.
The new multi touch monitor is supported at the SIPLACE TX V2 placement machine. For this, a
new customized logoff is required. This will be done by a shortcut on the desktop. The logoff
command and the shortcut will be copied to the station computer with the new WES7 Configurator
version.
Additionally, the virtual keyboard can be disabled in the GUI Settings dialog.
12.11.1 Switching Off Cover Fan and Vacuum Pump Fan
The cover fan and vacuum pump fan of the SIPLACE TX V2 placement machine are switched off
automatically under certain circumstances. This will reduce the noise emission and save energy.
In the event of a long machine idle time, the vacuum pump is automatically switched off. After a
120 second cooling period, the fans of the cover and vacuum pump will be switched off. By
switching on the vacuum pump, the fans will be switched on again.
The Automatically switch off the compressed air option must be enabled.
The fans will not be switched off if the vacuum pump is switched off temporarily, e.g. for zero
pressure adjustment.
12.12 SIPLACE C&P20 P2 – New Placement Head
Compatible mode: Hidden
The new SIPLACE C&P20 P2 placement head is supported on the SIPLACE TX V2 placement
machine. A new 6xxx nozzle series has been introduced for this placement head. This nozzle
series is also supported by the C&P20 P placement head.
12.13 SST48 and SST49 – New Camera Types
Compatible mode: Hidden
The GigE camera types SST48 and SST49 are supported for the C&P20 M2, C&P20 P and C&P20
P2 placement heads.
For calibration of the SST49 camera, a new calibration tool must be used. This calibration tool can
be used for all cameras and requires new nozzle types as described below.