SIPLACE Station Software 7xx to 714 介绍 - 第244页

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 244 Check Alive Response A placement machine may request an immediate response t o its CheckAlive mess age. Request Board Informati on A placeme…

100%1 / 290
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
243
13 Feature Description Station Software V712.x
Features (V712.0 (R18-2): Compatible Mode 711.2)
13.1 Customer-specific Nozzles Improvements
Compatible mode: Hidden
The treatment of customer-specific nozzles has been improved as follows:
Nozzle ID
Customer-specific nozzles for the C&P20 P and CPP heads can be equipped with a nozzle ID. A
nozzle ID can be specified for 6xxx, 4xxx, 2xxx and 28xx customer-specific nozzles in SIPLACE
Pro. The nozzle ID will be sent to the station when a job is downloaded from SIPLACE Pro.
Automatic Nozzle ID Recognition
The automatic nozzle ID recognition can be performed for the customer-specific nozzles in the
same way as for standard nozzles. For more information, please refer to the description in section
7.11 of the Feature Description 7xx, item no. [00197741-xx].
Display Customer-Specific Nozzles at the Station
The name of customer-specific nozzles will be displayed in an additional line in the Head view
(Current and Specified columns) and Nozzle Changer view (Current and Replace with columns)
respectively. The name will not be stored and is only displayed when a job is downloaded from
SIPLACE Pro.
Contamination Scan
Please refer to section 13.15.10.
13.2 "IPC-HERMES-9852" Enhancements
Compatible mode: Complete
Following enhancements have been made in the implementation of the "IPC-HERMES-9852"
protocol for Hermes 1.1 for the placement machines:
Machine support
The station software also supports "IPC-HERMES-9852" on the SIPLACE SX1/SX2 placement
machines.
Board Forecast
A new BoardForecast message announces a new board or just a product with no board available.
In addition, length, width and thickness have been added to the MachineReady message to
indicate for which type of board the machine is ready.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
244
Check Alive Response
A placement machine may request an immediate response to its CheckAlive message.
Request Board Information
A placement machine may query its predecessor for the board ID of a board via its top or bottom
barcode. Default number of persisted boards: 100 per lane.
The board data will not be stored and gets lost if the machine is shut down.
Board Weight
The weight attribute in the BoardAvailable message specifies an optional board weight.
Interface ID in the Configuration
For equipment with multiple input/output ports, an additional ID in the configuration message
differentiates between them.
13.3 OSC Package Option Enhancements
Compatible mode: Hidden
Detailed information on the OSC Package features can be found in the OSC Package User Guide,
item no. [00198374-xx].
The main enhancements made for the OSC Package Option in the station software and SIPLACE
Vision are listed in the overview below.
Snap-In Detection
The board data will not be deleted when the board is removed for inspection.
Improved teaching step:
It is no more required to let just one board enter the machine for teaching. When the
components of the first board with Snap-In positions have been placed, the next board will not
be placed until the Snap-In positions on the first board have been verified by the operator.
Restrictions
Not supported on SIPLACE CA4 and CA4 V2 placement machines.
Stereo Measurement
Until now, only THT pins were supported for stereo measurement. As of SIPLACE Vision
version 5.6.1, Pattern Features and Gullwing lead group types are supported additionally.
Optionally, a new option (4x image capture) can be used to try to improve the height resolution
and reduce the minimal feature size.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
245
Pin-in-Paste Height Check for TH and CPP Placement Heads
The Pin-in-paste height check is supported for the TH and CPP placement heads. The
functionality is the same as for the existing height measurement in the Snap-In detection for the
Twin VHF placement head, but the components have centering pins instead of board locks.
Restrictions
Not supported on SIPLACE CA4 and CA4 V2 placement machines.
Only supported together with station software version >=712.0. If the line does not contain any
station with station software >=712.0, the feature is ignored, and a warning displayed.
Increased Placement Force for TH Placement Head
The placement force has been increased to maximum 30 N for the TH placement head.
Restrictions
Not supported on SIPLACE X-Series placement machines.
Automatic Illumination Adjustment
If an odd shape component (type Non-standard or Connector) cannot be recognized sufficiently
during teaching at the station or Vision Teach Station, an automatic illumination adjustment can be
performed. For this, the new Start optimization button must be selected in the Set component
position for optimization dialog of SIPLACE Vision.
13.4 CPP Placement Head Increased Placement Force and
Component Weight
The placement force has been increased to maximum 15 N for the CPP placement head. The
component weight has been increased to 20 g in Pick&Place mode.
13.5 Smart Pin Support Enhancements
13.5.1 Smart Pin Support for SIPLACE TX V2-Series
Compatible mode: Hidden
The automatic Smart Pin Support option is supported for the SIPLACE TX V2-series placement
machines with two gantries TX2 V2 and TX2 V2i. The fixed Smart Pin Magazine occupies the
tracks 1-6 on a new table type. As default, five pins per lane are required. Optionally, an additional
pin magazine can be put on the station and up to ten pins set per lane. The Smart Pin Magazine
can be locked and unlocked in the Manual Operations view for the location.
The first nozzle magazine(s) of the nozzle changer on the left side cannot be used.
When a job with pins is downloaded to the station, the station verifies if the pins can be placed on
all programmed positions. In case the pins cannot be placed (e.g. because of screws in the lifting
table), an error message is displayed that informs the operator why the job cannot be accepted.
During the production specification, following new detailed errors may occur:
Calibration garage is not empty
The operator must empty the calibration garage.
Support pin for automatic calibration is missing
The operator must insert a support pin in the placement head.