SIPLACE Station Software 7xx to 714 介绍 - 第274页

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 274 NOTICE Please note that this feature is not displayed with any icon in the p roduction view for either state (switched on/off). 14.22 Verify…

100%1 / 290
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
273
On the master station, only the Synchronize recalibrations option is visible. If the option is
activated, the recalibration is synchronized along the line. If the option is deactivated, all machines
recalibrate independently.
NOTICE
The Synchronize recalibrations option can only be activated or deactivated on the
master station.
Figure 14-7: Machine neighborhood view with recalibration information on a master station
On a non-master station, the name of the master station (if available) and the connection status to
the master station are additionally displayed. If the master station is highlighted in green, the
connection is established successfully. If the master station is highlighted in red, the connection
failed, e.g. because the master station is offline.
Figure 14-8: Machine neighborhood view with recalibration information on a non-master station
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
274
NOTICE
Please note that this feature is not displayed with any icon in the production view for
either state (switched on/off).
14.22 Verifying Vacuum Tooling by Barcode Fiducial
Compatible mode: Not supported
Vacuum tooling uses suction to pick up a PCB and hold it precisely and level on a vacuum plate
(tool top plate of vacuum tooling) during the placement process, establishing optimal conditions for
accurate placement. The different vacuum tooling types are often designed for specific PCB types
only. Using a wrong vacuum tooling type can not only lead to inaccurate placements, but also to
damaging or destroying a PCB. To make sure that the correct vacuum tooling types have been
installed in the station, they must be checked against the vacuum tooling types defined in the
vacuum tooling configurations specified in SIPLACE Pro.
Whenever you use vacuum tooling in a station, you need to configure it in the recipe in SIPLACE
Pro and in the station software. To verify that the correct vacuum tooling has been installed in the
station, the configuration on the station is compared with the specifications in the recipe.
To automatically identify the vacuum tooling installed in the station, a barcode fiducial can be used
that is placed on the vacuum tooling surface. The barcode contains information on the vacuum
tooling, e.g. its name and exact vacuum tooling type.
In order to locate the barcode on the vacuum tooling, the following parameters must be specified in
SIPLACE Pro:
The dimension of the vacuum tooling (length and width)
The X-/Y-offset of the barcode fiducial in relation to the reference point
The reference to the barcode fiducial
The barcode verification string
During recipe download, when the conveyor is empty, the lifting table is lifted to upper position,
where the barcode on the tooling surface can be scanned by the PCB camera. The information
contained on the barcode is then compared to the specifications in the recipe. If the barcode
cannot be read, if the vacuum tooling type is unknown, or if the information in the barcode does not
match the data stored in the station software configuration, a detailed error message is displayed:
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
275
Figure 14-9: Displayed error message if barcode information does not match recipe
In the Current machine requests for teaching view in the station GUI, the Hardware fiducials
tab has been added, providing a list of hardware fiducials that must be taught. This tab also
contains the barcodes for vacuum tooling.
Figure 14-10: List of vacuum tooling barcodes that need to be taught
NOTICE
The position of the barcode cannot be changed in the station software.