SIPLACE Station Software 7xx to 714 介绍 - 第86页
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 86 7.22 Improved Lamp Indicator Control for Empty Trays in MTC an d WPC If the trays in MTC or WPC are empty the lamp indicator f lashes. In for…

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
85
Checking the configuration
A feasibility check is performed for the configuration after machine booting (e.g., if WDTL is active
on the station only but not in SIPLACE Pro).
At the station the activation and configuration can be checked on the station console under
Configuration – Component …\Domains\Domains\Production\WhisperServer.
Figure 7-22: Checking configuration
If the barcode has been successfully read and the CreateAction feature was activated at the
station, the inkspot file will be created on the configured shared drive after the board has been
placed.

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
86
7.22 Improved Lamp Indicator Control for Empty Trays in MTC and
WPC
If the trays in MTC or WPC are empty the lamp indicator flashes. In former station software
versions, the lamp indicators also flashed for empty trays in a family setup which were not required
for the current product in the line
As of this station software version the operator can set the time in minutes as threshold value for
the lamp indicators on the GUI for trays in MTC and WPC which are not controlled by Setup
Center.
Figure 7-23: Setting threshold value for lamp indicators
At every pickup action from a tray of the MTC or WPC a calculation is performed, for how long the
boards can be completely produced with the available components (please refer to section 7.7
Display of Remaining Time in the Filling Level View). The components of the entire chain are
considered in the calculation, i.e. if multiple trays are available the total number of components of
all trays is used.

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
87
If the defined time threshold is reached, an error message is displayed on the GUI and the
corresponding lamp indicator is activated. This happens whether the trays are empty or not.
Figure 7-24: Threshold value reached
If a single tray is empty, this is only displayed by an error message and orange-marked tray level
on the GUI. The lamp indicators are not activated.
Figure 7-25: Single tray empty