JO-116-001_w.pdf - 第135页
4-50 JO-1 16 1 105-001 4. Default Setting of Program for Feeder Measurement ¡ : Measurement Possible with Feeder Adjusting Jig r : The data measured by the height gauge can be t ransferred to the feeder adjusting jig. …

4-49
JO-116
1105-001
4. Default Setting of Program for Feeder Measurement
¡
: Measurement Possible with Feeder Adjusting Jig
r
: The data measured by the height gauge can be transferred to the
feeder adjusting jig.
×
: Measurement Impossible
Table D11
Feeder Models GD08080 GD08081
Offset
Name
Lane #1 Origin Offset
¡
×
¡
×
Lane #2 Origin Offset
¡
×
¡
×
Lane #1 Offset X
¡ ¡ ¡ ¡
Lane #1 Offset Y
¡ ¡ ¡ ¡
Lane #1 Offset Z
r r r r
Lane #2 Offset X
¡ ¡ ¡ ¡
Lane #2 Offset Y
¡ ¡ ¡ ¡
Lane #2 Offset Z
r r r r
Required Master Tape Models
JG-0009-12 JG-0009-12 JG-0009-12 JG-0009-12
Program Nos. (Initial Setting Mode)
17 18 19 20
Item Type Name
GD08080
-8×2_ORG/XY
GD08080
-8×2_XY
GD08081
-8×2_ORG/XY
GD08081
-8×2_XY
Type Name Type ID Nos.
(1 to N)
1 1 1 1
Inspection Type Nos. (1 to 5)
3 2 3 2
# of Sprocket Feeding Times
(1 to 100)
90 90 90 90
Sprocket Feeding Interval
(1 to 100)
9 9 9 9
Sprocket Feeding Delay (ms)
0 0 0 0
# of Components per
Sprocket Circle
90 90 90 90
Component Pitch (mm)
2.000 2.000 2.000 2.000
Lot Data Input Omission
Flag (0 or 1)
1 1 1 1
Fiducial Mark Position X
-3.650 -3.650 -3.650 -3.650
Fiducial Mark Position Y
-13.000 -13.000 -13.000 -13.000
Sprocket Feed Basic
Pitch Y
2.000 2.000 2.000 2.000
# of Divided Pulses for
Origin Offset Adjustment
256 256 256 256
# of Measured Pickup
Holes (1 or 2)
2 2 2 2
Measured Pickup Hole
Position #1 X
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #1 Y
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #2 X
9.500 9.500 9.500 9.500
Measured Pickup Hole
Position #2 Y
0.000 0.000 0.000 0.000
Feeder parameter le
(Before measurement)
GD08080-00000A.fdr GD08080-00000A.fdr GD08081-00000A.fdr GD08081-00000A.fdr
Feeder parameter le
(After measurement)
GD08080-00000B.fdr GD08080-00000B.fdr GD08081-00000B.fdr GD08081-00000B.fdr

4-50
JO-116
1105-001
4. Default Setting of Program for Feeder Measurement
¡
: Measurement Possible with Feeder Adjusting Jig
r
: The data measured by the height gauge can be transferred to the
feeder adjusting jig.
×
: Measurement Impossible
Table D12
Feeder Models GD08082 GD08083
Offset
Name
Lane #1 Origin Offset
¡
×
¡
×
Lane #2 Origin Offset
¡
×
¡
×
Lane #1 Offset X
¡ ¡ ¡ ¡
Lane #1 Offset Y
¡ ¡ ¡ ¡
Lane #1 Offset Z
r r r r
Lane #2 Offset X
¡ ¡ ¡ ¡
Lane #2 Offset Y
¡ ¡ ¡ ¡
Lane #2 Offset Z
r r r r
Required Master Tape Models
JG-0009-12 JG-0009-12 JG-0009-12 JG-0009-12
Program Nos. (Initial Setting Mode)
21 22 23 24
Item Type Name
GD08082
-8×2_ORG/XY
GD08082
-8×2_XY
GD08083
-8×2_ORG/XY
GD08083
-8×2_XY
Type Name Type ID Nos.
(1 to N)
1 1 1 1
Inspection Type Nos. (1 to 5)
3 2 3 2
# of Sprocket Feeding Times
(1 to 100)
90 90 90 90
Sprocket Feeding Interval
(1 to 100)
9 9 9 9
Sprocket Feeding Delay (ms)
0 0 0 0
# of Components per
Sprocket Circle
90 90 90 90
Component Pitch (mm)
2.000 2.000 2.000 2.000
Lot Data Input Omission
Flag (0 or 1)
1 1 1 1
Fiducial Mark Position X
-3.650 -3.650 -3.650 -3.650
Fiducial Mark Position Y
-13.000 -13.000 -13.000 -13.000
Sprocket Feed Basic
Pitch Y
2.000 2.000 2.000 2.000
# of Divided Pulses for
Origin Offset Adjustment
256 256 256 256
# of Measured Pickup
Holes (1 or 2)
2 2 2 2
Measured Pickup Hole
Position #1 X
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #1 Y
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #2 X
9.500 9.500 9.500 9.500
Measured Pickup Hole
Position #2 Y
0.000 0.000 0.000 0.000
Feeder parameter le
(Before measurement)
GD08082-00000A.fdr GD08082-00000A.fdr GD08083-00000A.fdr GD08083-00000A.fdr
Feeder parameter le
(After measurement)
GD08082-00000B.fdr GD08082-00000B.fdr GD08083-00000B.fdr GD08083-00000B.fdr

4-51
JO-116
1105-001
4. Default Setting of Program for Feeder Measurement
¡
: Measurement Possible with Feeder Adjusting Jig
r
: The data measured by the height gauge can be transferred to the
feeder adjusting jig.
×
: Measurement Impossible
Table D13
Feeder Models GD12160 GD24320
Offset
Name
Lane #1 Origin Offset
¡
×
¡
×
Lane #2 Origin Offset
- - - -
Lane #1 Offset X
¡ ¡ ¡ ¡
Lane #1 Offset Y
¡ ¡ ¡ ¡
Lane #1 Offset Z
r r r r
Lane #2 Offset X
- - - -
Lane #2 Offset Y
- - - -
Lane #2 Offset Z
- - - -
Required Master Tape Models
JG-0009-16 JG-0009-16 JG-0009-17 JG-0009-17
Program Nos. (Initial Setting Mode)
25 26 27 28
Item Type Name
GD12160
-16×4_ORG/XY
GD12160
-16×4_XY
GD24320
-32×4_ORG/XY
GD24320
-32×4_XY
Type Name Type ID Nos.
(1 to N)
2 2 3 3
Inspection Type Nos. (1 to 5)
3 2 3 2
# of Sprocket Feeding Times
(1 to 100)
45 45 45 45
Sprocket Feeding Interval
(1 to 100)
5 5 5 5
Sprocket Feeding Delay (ms)
0 0 0 0
# of Components per
Sprocket Circle
60 60 60 60
Component Pitch (mm)
4.000 4.000 4.000 4.000
Lot Data Input Omission
Flag (0 or 1)
1 1 1 1
Fiducial Mark Position X
13.950 13.950 13.950 13.950
Fiducial Mark Position Y
-13.000 -13.000 -13.000 -13.000
Sprocket Feed Basic
Pitch Y
2.000 2.000 2.000 2.000
# of Divided Pulses for
Origin Offset Adjustment
256 256 256 256
# of Measured Pickup
Holes (1 or 2)
1 1 1 1
Measured Pickup Hole
Position #1 X
4.100 4.100 -2.600 -2.600
Measured Pickup Hole
Position #1 Y
-2.000 -2.000 -6.000 -6.000
Feeder parameter le
(Before measurement)
GD12160-00000A.fdr GD12160-00000A.fdr GD24320-00000A.fdr GD24320-00000A.fdr
Feeder parameter le
(After measurement)
GD12160-00000B.fdr GD12160-00000B.fdr GD24320-00000B.fdr GD24320-00000B.fdr