JO-116-001_w.pdf - 第138页

4-53 JO-1 16 1 105-001 4. Default Setting of Program for Feeder Measurement ¡ : Measurement Possible with Feeder Adjusting Jig r : The data measured by the height gauge can be t ransferred to the feeder adjusting jig. …

100%1 / 161
4-52
JO-116
1105-001
4. Default Setting of Program for Feeder Measurement
¡
: Measurement Possible with Feeder Adjusting Jig
r
: The data measured by the height gauge can be transferred to the
feeder adjusting jig.
×
: Measurement Impossible
Table D14
Feeder Models GD44560 GD72000
Offset
Name
Lane #1 Origin Offset
¡
×
¡
Lane #2 Origin Offset
- - -
Lane #1 Offset X
¡ ¡ ¡
Lane #1 Offset Y
¡ ¡ ¡
Lane #1 Offset Z
r r r
Lane #2 Offset X
- - -
Lane #2 Offset Y
- - -
Lane #2 Offset Z
- - -
Required Master Tape Models
JG-0009-18 JG-0009-18 JG-0009-20
Program Nos. (Initial Setting Mode)
29 30 31
Item Type Name
GD44560
-44×4_ORG/XY
GD44560
-44×4_XY
GD72000
-72×4_ORG/XY
Type Name Type ID Nos.
(1 to N)
4 4 5
Inspection Type Nos. (1 to 5)
3 2 3
# of Sprocket Feeding Times
(1 to 100)
45 45 45
Sprocket Feeding Interval
(1 to 100)
5 5 5
Sprocket Feeding Delay (ms)
0 0 0
# of Components per
Sprocket Circle
60 60 60
Component Pitch (mm)
4.000 4.000 4.000
Lot Data Input Omission
Flag (0 or 1)
1 1 1
Fiducial Mark Position X
13.950 13.950 13.950
Fiducial Mark Position Y
-13.000 -13.000 -13.000
Sprocket Feed Basic
Pitch Y
2.000 2.000 2.000
# of Divided Pulses for
Origin Offset Adjustment
256 256 256
# of Measured Pickup
Holes (1 or 2)
1 1 1
Measured Pickup Hole
Position #1 X
-8.600 -8.600 -8.600
Measured Pickup Hole
Position #1 Y
-14.000 -14.000 -14.000
Feeder parameter le
(Before measurement)
GD44560-00000A.fdr GD44560-00000A.fdr GD72000-00000A.fdr
Feeder parameter le
(After measurement)
GD44560-00000B.fdr GD44560-00000B.fdr GD72000-00000B.fdr
4-53
JO-116
1105-001
4. Default Setting of Program for Feeder Measurement
¡
: Measurement Possible with Feeder Adjusting Jig
r
: The data measured by the height gauge can be transferred to the
feeder adjusting jig.
×
: Measurement Impossible
Table D15
Feeder Models GT18080 GT18081
Offset
Name
Lane #1 Origin Offset
¡
×
¡
×
Lane #2 Origin Offset
¡
×
¡
×
Lane #1 Offset X
¡ ¡ ¡ ¡
Lane #1 Offset Y
¡ ¡ ¡ ¡
Lane #1 Offset Z
r r r r
Lane #2 Offset X
¡ ¡ ¡ ¡
Lane #2 Offset Y
¡ ¡ ¡ ¡
Lane #2 Offset Z
r r r r
Required Master Tape Models
JG-0009-12 JG-0009-12 JG-0009-12 JG-0009-12
Program Nos. (Initial Setting Mode)
33 34 35 36
Item Type Name
GT18080
-8×2_ORG/XY
GT18080
-8×2_XY
GT18081
-8×2_ORG/XY
GT18081
-8×2_XY
Type Name Type ID Nos.
(1 to N)
1 1 1 1
Inspection Type Nos. (1 to 5)
3 2 3 2
# of Sprocket Feeding Times
(1 to 100)
90 90 90 90
Sprocket Feeding Interval
(1 to 100)
9 9 9 9
Sprocket Feeding Delay (ms)
0 0 0 0
# of Components per
Sprocket Circle
90 90 90 90
Component Pitch (mm)
2.000 2.000 2.000 2.000
Lot Data Input Omission
Flag (0 or 1)
1 1 1 1
Fiducial Mark Position X
-3.650 -3.650 -3.650 -3.650
Fiducial Mark Position Y
-13.000 -13.000 -13.000 -13.000
Sprocket Feed Basic
Pitch Y
2.000 2.000 2.000 2.000
# of Divided Pulses for
Origin Offset Adjustment
256 256 256 256
# of Measured Pickup
Holes (1 or 2)
2 2 2 2
Measured Pickup Hole
Position #1 X
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #1 Y
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #2 X
9.500 9.500 9.500 9.500
Measured Pickup Hole
Position #2 Y
0.000 0.000 0.000 0.000
Feeder parameter le
(Before measurement)
GT18080-00000A.fdr GT18080-00000A.fdr GT18081-00000A.fdr GT18081-00000A.fdr
Feeder parameter le
(After measurement)
GT18080-00000B.fdr GT18080-00000B.fdr GT18081-00000B.fdr GT18081-00000B.fdr
4-54
JO-116
1105-001
4. Default Setting of Program for Feeder Measurement
¡
: Measurement Possible with Feeder Adjusting Jig
r
: The data measured by the height gauge can be transferred to the
feeder adjusting jig.
×
: Measurement Impossible
Table D16
Feeder Models GT18082 GT18083
Offset
Name
Lane #1 Origin Offset
¡
×
¡
×
Lane #2 Origin Offset
¡
×
¡
×
Lane #1 Offset X
¡ ¡ ¡ ¡
Lane #1 Offset Y
¡ ¡ ¡ ¡
Lane #1 Offset Z
r r r r
Lane #2 Offset X
¡ ¡ ¡ ¡
Lane #2 Offset Y
¡ ¡ ¡ ¡
Lane #2 Offset Z
r r r r
Required Master Tape Models
JG-0009-12 JG-0009-12 JG-0009-12 JG-0009-12
Program Nos. (Initial Setting Mode)
37 38 39 40
Item Type Name
GT18082
-8×2_ORG/XY
GT18082
-8×2_XY
GT18083
-8×2_ORG/XY
GT18083
-8×2_XY
Type Name Type ID Nos.
(1 to N)
1 1 1 1
Inspection Type Nos. (1 to 5)
3 2 3 2
# of Sprocket Feeding Times
(1 to 100)
90 90 90 90
Sprocket Feeding Interval
(1 to 100)
9 9 9 9
Sprocket Feeding Delay (ms)
0 0 0 0
# of Components per
Sprocket Circle
90 90 90 90
Component Pitch (mm)
2.000 2.000 2.000 2.000
Lot Data Input Omission
Flag (0 or 1)
1 1 1 1
Fiducial Mark Position X
-3.650 -3.650 -3.650 -3.650
Fiducial Mark Position Y
-13.000 -13.000 -13.000 -13.000
Sprocket Feed Basic
Pitch Y
2.000 2.000 2.000 2.000
# of Divided Pulses for
Origin Offset Adjustment
256 256 256 256
# of Measured Pickup
Holes (1 or 2)
2 2 2 2
Measured Pickup Hole
Position #1 X
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #1 Y
0.000 0.000 0.000 0.000
Measured Pickup Hole
Position #2 X
9.500 9.500 9.500 9.500
Measured Pickup Hole
Position #2 Y
0.000 0.000 0.000 0.000
Feeder parameter le
(Before measurement)
GT18082-00000A.fdr GT18082-00000A.fdr GT18083-00000A.fdr GT18083-00000A.fdr
Feeder parameter le
(After measurement)
GT18082-00000B.fdr GT18082-00000B.fdr GT18083-00000B.fdr GT18083-00000B.fdr