5-4 JO-1 16 3. Layout 1 105-001 3. Layout 3.1 Electrical Box Z01 Noise Filter Surge Protector G01 DC Power Supply PCB H01 Lamp Q01 Breaker DC Power Supply for G02 Multiplexer K01 Relay Note The jig in the above inset pho…

100%1 / 161
5-3
JO-116
2. Others
1105-001
2. Others
Shape of Connector
D-Sub 15 Pins (Socket Type)
Contents of Signals and Pin Nos.
Table E1
Pin
Nos.
I/O Contents of Signals Remarks
1 POW Output +24V-1 +24V through Relay
2 POW Output +24V-1 +24V through Relay
3 POW GND-1 GND through Relay
4 POW GND-1 GND through Relay
5 POW Output +24V Clamp Switch
6 Input Feeder Clamp Switch Clamping at Short Circuit
7 Output Feeder Send Signal Lane #1 ON at Short Circuit
8 Output Feeder Send Signal Lane #2 ON at Short Circuit
9 Input Feeder Action Complete Signal Action Complete at Short Circuit
10 Input Feeder Connection Check Signal 1 Connected at Short Circuit
11 Input Feeder Connection Check Signal 2 Connected at Short Circuit
12 - Reserved
13 RS-TXD RS232C Communication TXD RS232C Communication
14 RS-RXD RS232C Communication RXD RS232C Communication
15 RS-GND RS232C Communication GXD RS232C Communication
Note
"Input" and "Output" are the signal directions viewed from the control
section.
5-4
JO-116
3. Layout
1105-001
3. Layout
3.1 Electrical Box
Z01 Noise Filter
Surge Protector
G01 DC Power Supply
PCB
H01 Lamp
Q01 Breaker
DC Power Supply
for G02 Multiplexer
K01 Relay
Note
The jig in the above inset photo might look different from the actual one.
5-5
JO-116
4. Electrical Circuit Diagram
1105-001
4. Electrical Circuit Diagram
N24
P24
N24
P24-1
P24
N24-1
1
4
7
2
5
8
3
6
9
10
11
+
OUT03
N24-1
1
2
4
3
1
2
3
4
1
2
3
4
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
10
11
12
13
14
15
15 15
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
1
2
3
4
5
6
7
8
9
RS-TXD
RS-RXD
RS-GND
CD
RD
SD
DTR
GND
DSR
RTS
CTS
P9
1
2
3
4
5
6
7
8
9
FEED-START1
FEED-BUSY
FEED-P24
FEEDR-SET1
FEEDR-GND
FEED-START2
FEEDR-SET2
RS-TXD
RS-RXD
RS-GND
FEEDR-S3POW
FDR-MSSG
1
1
2
3
4
5
6
6
1
1
2
3
4
5
6
6
1
1
2
3
4
4
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
+24V
+24V
GND
GND
GND
TXD(RS232C)
RXD(RS232C)
1
1
2
3
4
5
6
6
1
1
2
3
4
5
6
6
1
1
2
3
4
4
P24-1
P24-1
N24-1
N24-1
P24
FDR-SET-MS
FEED-START1
FEED-START2
FEED-BUSY
FEEDDR-SET1
FEEDDR-SET2
RS-GND
RS-TXD
RS-RXD
N24
P24
P24
P24
N24
IN01
IN02
IN03
IN04
IN05
IN06
IN07
IN17
IN10
IN11
IN12
IN13
IN14
IN15
IN16
OUT01
OUT02
OUT03
OUT04
OUT05
OUT06
OUT07
OP 2/3
OUT17
OUT10
OUT11
OUT12
OUT13
OUT14
OUT15
OUT16
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
37
PIO-16/16L(PCI)H
ON 2/3
ON 2/3
IN00
IP 0/1
NC
OUT00
H01
X21
X22 X23
X12 X12
X1 X1
X2 X2
X3 X3
X16
Micro-SW
S01
X13
X11 X11
X24 X24
P24-1
K01
GND
OP
ON
10S
E
10R
G01
PC
G02
Q01
F01
Z01
L1
L2
N1
PE
Surge Protector
N2
N
L
LED Illumination
Lighting Surge Protector
Multiplexer Monitor
PC USB Port
Lane #1 Feed Command
Lane #2 Feed Command
READY Signal
Connection Check Signal
(For Communication Check)
Connection Check Signal
(GND Turn-Around)
Wiring in Electrical Box
Case
14