3-17
JO-116
1105-001
4. "Type Setting" Window
Manual Type Change
Specication in "Type Listup"
Window When the "Type Setting" window is active, press the [Setting]
button.
The "Type Listup" window opens.
Use the [Page Selection] or [Cursor Movement] button to move the
subcursor to the target type No.
Note
The subcursor can also be moved by clicking the scroll bar, directly
the No. of the pertinent line in the list, or the type name area.
Press the [Type Change] button.
The type data corresponding to the No. specied by the subcursor is
called and displayed.
Subcursor
[Page Selection] Button
[Cursor Movement]
Button
Fig. C13 "Type Listup" Window
3-18
JO-116
1105-001
5. "System Setting" Window
5. "System Setting" Window
In the "System Setting" window, the set value peculiar to the machine can be
dened
(1) How to open the "System Setting" window
Only "Administrator" can open the "System Setting" window and
change the settings.
Change the current authority level to "Administrator".
Reference
Refer to "1. Administrative Authority Change" in "Section 3" for
how to change the authority.
Make the subcursor appear in the "Type Listup" window and press the
[Setting] button.
Note
The subcursor can be located at any place regardless of whether the
type data is already registered or not.
Used to print the
system data.
Used to move
the cursor.
The entry window
for the pertinent set
value opens,
enabling you to change
the set value.
Fig. C14 "System Setting" Window
3-19
JO-116
1105-001
5. "System Setting" Window
(2) Outline of Each System Data
Control Mode
The set data is used to change the control mode.
"0" or "1" can be set.
0:
Through Mode
(Operator Conrmation Omitted at Accuracy Inspection)
1:
Step Mode
(Operator Conrmation Displayed
Communication Timeout Value
Specify the time at which the "Communication Impossible" mode
should be detected in the RS232C serial communication.
Unit:
seconds
Alarm Buzzer Mode
Specify the period of time during which the buzzer should sound when
an error has occurred.
When "0" is set, the buzzer keeps on sounding until it is stopped with
the buzzer button.
"0" or "0.1 to 600.0 seconds (10 minutes)" can be set.
Log Data Folder
Specify the folder in which the inspection data log le should be saved.
Up to 62 characters can be used for the registration.
# of Feed Times from Sprocket
Specify the number of master tape idle feeding times required at the
start of the inspection.
A value "0 to 10" can be set.
Master Position #1 X and Y/Master Position #2 X and Y
The set parameters represent the inspection positions of the master
feeder.