3-27 JO-1 16 1 105-001 6.1 Accuracy Measurement T able [Print] Button When pressed, this button prints the item(s) selected by your selection mode. Select the print options in the "Print Setting" group box. Acc…

3-26
JO-116
1105-001
6.1 Accuracy Measurement Table
Selection Modes
When you tick a blank check box (
£
), a checkmark appears inside the check
box (
), indicating that the item is selected.
Some selection options are available.
All Selection :
Click the [Sel All] button located on the
lower right corner of the window.
Single Selection (Mouse) :
Double-click the item to be selected.
Single Selection (Keyboard) :
Move the cursor to the item to be selected
and press the [Space] key.
Multiple Selection (Mouse) :
Press the left button of the mouse and drag
the pointer to the items to be selected.
After that, click the right button of the
mouse. A pop-up window opens. Click
"Select".
When the items cannot be selected by
clicking, press the [Space] key on the
keyboard.
Multiple Selection (Keyboard) :
While pressing the [Shift] key, move the
cursor to the items to be selected and press
the [Space] key.
Fig. C21

3-27
JO-116
1105-001
6.1 Accuracy Measurement Table
[Print] Button
When pressed, this button prints the item(s) selected by your selection mode.
Select the print options in the "Print Setting" group box.
Accuracy Table :
The results of up to 50 feeders can be
printed on a piece of A4 paper.
Preview :
The contents (related to up to three
feeders) in the preview window
(displayed on the right pane) can be
printed on a piece of A4 paper.
Deletes from table after printing :
After printing is executed, the le of
the accuracy results is transferred to
another folder to make it clear if the le
is already printed or not.
(Path to Folder: D:\MeasureComp)

3-28
JO-116
1105-001
6.2 Chart
6.2 Chart
There are four kinds of charts. The tabs in the "Chart" window can be used to
select a chart.
6.2.1 Line Chart for Errors
This line chart indicates the results of inspection for each individual
holes.
Yellow Line
: X Values
Light Blue Line
: Y Values
White Solid Line
: CENTER Values
White Dashed Line
: 0 Values
Displayed from the top are "X in Lane #1", "Y in Lane #1", "X in Lane
#2", and "Y in Lane #2".
Fig. C22