0305-001 Tg0860-PM-MM *5 [TEACH ST ART] Key When this key is selected and the [MOVE] button is pressed, the P .E.C. recognition camera moves to the specified position of the selected vibratory stick feeder unit. The teac…

0305-001 Tg0860-PM-MM
6.8.3 Vibratory Stick Feeder Unit Offset
• The offset data for the vibratory stick feeder unit can be taught through
manual alignment operation.
When the [VIBRATE STICK FDR. UNIT OFFSET] key is pressed at the
“UNIT MANUAL ALIGNMENT TEACH” display, the following display ap-
pears on the screen.
*1 UNIT #
Set the vibratory stick feeder unit No. for manual alignment and teaching
operations.
*2 [ NEXT UNIT] and [ PREV. UNIT] Keys
Every time the [ NEXT UNIT] key is pressed, the unit No. increases by 1.
Every time the [ PREV. UNIT] key is pressed, the unit No. decreases by 1.
*3 [RECOG MARK DATA EDIT] Key
When this key is pressed, the “RECOG. MARK DATA EDIT” display (Fig.
4C168) appears on the screen, enabling the designation of a template shape
to appear on the recognition monitor.
The template shape can be specified for manual alignment with the align-
ment point.
Refer to “6.8.8 Editing of Recognition Mark Data” for details.
*4 [ALL BEAM HEADS ZERO] Key
Both Beams A and B are zeroed.
When this key is selected and the [MOVE] button is pressed, the zeroing
operation starts.
3-88
6.8 UNIT MANUAL ALIGNMENT TEACH Display
Fig. 4C160
*1
*2
*5
*4
*3
*6
*7

0305-001 Tg0860-PM-MM
*5 [TEACH START] Key
When this key is selected and the [MOVE] button is pressed, the P.E.C.
recognition camera moves to the specified position of the selected vibratory
stick feeder unit.
The teaching point of the vibratory stick feeder unit appears on the recogni-
tion monitor. Perform the manual alignment using the track ball.
Refer to “6.8.9 Teaching Operation with Trackball” for details.
*6 OLD DATA
Displayed are the values (the parameters related to the indicated unit #)
before the vibratory stick feeder unit offset data is taught.
*7 NEW DATA
Displayed are the values (the parameters related to the indicated unit #)
after the vibratory stick feeder unit offset data is taught.
Before the teaching operation is performed, the same values as *6 are dis-
played.
3-89
6.8 UNIT MANUAL ALIGNMENT TEACH Display

0305-001 Tg0860-PM-MM
6.8.4 Feeder (B) Offset
• After the actually used feeders are installed in each feeder slot No. and
manual alignment operation is performed, the offset values for the feeder
are taught.
When the [FEEDER (B) OFFSET] key is pressed at the “UNIT MANUAL
ALIGNMENT TEACH” display, the following display appears on the screen.
*1 FEEDER #
A feeder slot No. can be set for manual alignment and teaching operations.
Install the feeder to be used in the slot No. specified in the “FEEDER #”
data box.
*2 [ NEXT FDR. #] and [ PREV. FDR. #] Keys
When the [ NEXT FDR. #] key is pressed, the feeder # increases by 1.
When the [ PREV. FDR. #] key is pressed, the feeder # decreases by 1.
*3 [RECOG MARK DATA EDIT] Key
When this key is pressed, the “RECOG. MARK DATA EDIT” display (Fig.
4C168) appears on the screen, enabling the designation of a template shape
to appear on the recognition monitor.
The template shape can be specified for manual alignment with the align-
ment point.
Refer to “6.8.8 Editing of Recognition Mark Data” for details.
*4 [ALL BEAM HEADS ZERO] Key
Both Beams A and B are zeroed.
When this key is selected and the [MOVE] button is pressed, the zeroing
operation starts.
*1
*2
*5
*4
*3
*6
*7
3-90
6.8 UNIT MANUAL ALIGNMENT TEACH Display
Fig. 4C161