4OM-1011-002 - 第178页

0305-001 Tg0860-PM-MM 7. DEVICE TEST Display When the [DEVICE TEST] key is pressed at the “SPECIAL SEL.” display , the following display appears on the screen. *1 [P .E.C. RECOG TEST ] Key When this key is pressed, the “…

100%1 / 289
0305-001 Tg0860-PM-MM
*4 Date Indication
When the [TEACH OFFSET] key is pressed, each offset data is indicated.
In the case of “COMPONENT RECOG. CAMERA OFFSET”, pressing
the [SHIFT] key indicates the data for each head in turn.
Operation Procedure
(1) Select the [CAMERA
HEAD OFFSET] key and press the [MOVE]
button. The offsets of Nos. 1 to 4 are automatically taught in turn.
Note: In the following cases, the “CAMERA
HEAD OFFSET” teaching
can’t be performed.
If any one of the component recognition cameras is set to “Camera
Skip”.
If any one of the heads is set to “Head Skip”.
3-126
6.14 Camera Head Offset
0305-001 Tg0860-PM-MM
7. DEVICE TEST Display
When the [DEVICE TEST] key is pressed at the “SPECIAL SEL.” display, the
following display appears on the screen.
*1 [P.E.C. RECOG TEST] Key
When this key is pressed, the “P.E.C. RECOG TEST” dis-
play opens,enabling the test and check operations (whether
or not P.E.C. recognition can be performed normally) of
fiducial mark recognition function.
Menus are provided to prepare for creation of recognition
mark data.
*2 [COMPONENT RECOG TEST] Key
When this key is pressed, the “COMPONENT RECOG.
TEST” display opens, enabling the check operation of cre-
ated component library data.
Menus are provided to make a test on component recogni-
tion and check whether or not the component designated
using a test ID can normally be recognized.
Note: When the [OPERATION/SET UP] switch is set to
the “SET UP” side, the device test operation can-
not be performed.
*3 [X/Y BEAM TEST] Key
When this key is pressed, the “X/Y BEAM TEST” display
appears on the screen, enabling the activation of only the
X/Y beam according to the current pattern program.
Menus are provide to check pattern program data and de-
termine operation start step No. of semi-automatic opera-
tion for continuous operation of the machine to complete
unfinished P.C.B.’s.
7. DEVICE TEST Display
3-127
Fig. 4C246
*1
*2
*3
Fig. 4C247
Fig. 4C248
Fig. 4C249
0305-001 Tg0860-PM-MM
7.1 P.E.C. RECOG TEST Display
When the [P.E.C. RECOG TEST] key is pressed at the “DEVICE TEST” dis-
play, the following display appears on the screen.
Refer to the following sessions for detailed description of each data item.
Volume 2: “2.3.4 P.E.C. MARK DATA EDIT Display”
“5.10 P.E.C. RECOG CAMERA OFFSET Display”.
*1 P.E.C. RECOG CAMERA
Select the camera to be used for the P.E.C. recognition func-
tion.
<Options>
“CAM-A3” (Beam A)
“CAM-B3” (Beam B)
*2 FIDUCIAL MARK THETA
The parameter set in the “FIDUCIAL MARK THETA” data
box is unique for recognition test.
An angle must be set in the data box corresponding the
parameter set in the “MARK TYPE” data box at the “P.E.C.
MARK DATA EDIT” display.
Example:
Setting for equilateral triangle (upward)
: 0°
: 90°
: 180°
: 270°
*3 [X/Y BEAM MOVE] Key
When this key is pressed, the “X/Y BEAM MOVE” dis-
play appears on the screen.
7.1 P.E.C. RECOG TEST Display
3-128
Fig. 4C250
*1
*2
*3
*4
*5
*6
Fig. 4C251
Fig. 4C252