4OM-1011-002 - 第23页
0305-001 Tg0860-PM-MM Fig. 4A10 Scrap Box Fig. 4A1 1 Feeder Base and Scrap Box Fig. 4A12 Component Supply Section (Feeder) 4. Daily Maintenance 1-8 Component Discharge Box Abandonment Remove the components accumu- lated …

0305-001 Tg0860-PM-MM
1-7
Table 4A5
4. Daily Maintenance
4. Daily Maintenance
Vacuum Pump
Checking
Check the vacuum pressure visually.
Vacuum valve fully closed:
Min.-93kPa (Min.70cmHg) or more
During Operation:
Min.-60kPa (Min.45cmHg) or more
Fig. 4A8 Air Regulator
Fig. 4A9 Vacuum Pressure System
Maintenance Spots Check
Name
Fig.
No.
Description
Grease
Cleaning
Tools,
Nozzles, etc.
Air Regulator Main Air 4A8 Checking − − − − − − − − −
Air Blowing 4A8 Checking − − − − − − − − −
Vacuum Pressure
System
Vacuum Pump 4A9 Checking − − − − − − − − −
Empty Tape Box 4A10 Abandonment − − − − − − − − − Scrap Box
Component Discharge
Box
4A11 Abandonment − − − − − − − − −
Feeder Base Upper Surface of
Feeder Base
4A11 Cleaning − − − − − − − − −
Component
Supply Section
(Feeder)
Whole Body of Tape
Feeder
4A12 Checking and
Cleaning
− − − − − − − − −
Air Blowing
Checking
Check the air pressure visually.
0.015 MPa (0.15 kgf/cm
2
)
Main Air
Checking
Check the air pressure visually.
0.49 MPa (5 kgf/cm
2
)
Beam A Side
Beam B Side

0305-001 Tg0860-PM-MM
Fig. 4A10 Scrap Box
Fig. 4A11 Feeder Base and Scrap Box
Fig. 4A12 Component Supply Section (Feeder)
4. Daily Maintenance
1-8
Component Discharge Box
Abandonment
Remove the components accumu-
lated in the box.
Whole Body of Tape Feeder
Checking and Cleaning
Check it for damage or dirt. Clean
the tape feeder if it is dirty.
Upper Surface of Feeder Base
Cleaning
Remove the waste and foreign mate-
rial.
Beam B Side Beam A Side
Beam B Side
Beam A Side
Beam A Side
Beam B Side
Empty Tape Box
Abandonment
Remove the empty tapes.

0305-001 Tg0860-PM-MM
5. Weekly Maintenance
Table 4A6
5. Weekly Maintenance
1-9
Beam A Side
Drain
Cleaning
Drain water according to the following procedure.
(1) Place a container under the drain outlet.
(2) Turn slowly the cap on the bottom of the outer case
of each air filter in the direction of Arrow A.
Note: Take the greatest care because dirty water will
splash out from the outlet if the cap is turned
too much.
Ca
p
A
Fig. 4A13 Air Regulator
Maintenance Spots Check
Name
Fig.
No.
Description Grease
Cleaning
Tools,
Nozzles, etc.
Air Regulator Drain 4A13 Cleaning − − − Container,
etc.
Component
Recognition
Section
Protective Glass of
the Component
Recognition Camera
4A14 Cleaning − − − Rag, Air
Blow for
Camera
Upper Surface of
Fiducial Mark
4A14 Cleaning − − − Rag
Component Discharge
Box
4A14 Abandonment − − − − − − − − −
PCB Positioning
Section
Upper Surface of
Backup Table
4A15 Cleaning − − − Vacuum
Cleaner
Component
Supply Section
(Feeder)
Component Pick-Up
Position of Tape
Feeder
4A16 Cleaning − − − − − − − − −