4OM-1011-002 - 第77页

0305-001 Tg0860-PM-MM 3.3 Management Data (T ype 1) Keys and menus related to production performance of the machine are pro- vided, enabling the checking of overall performance data. When the [MANAGEMENT DA T A (TYPE 2)]…

100%1 / 289
0305-001 Tg0860-PM-MM
“Saved Data” : Shown are the parameters calculated just before the
cur rent parameters.
“Current Data” : Shown are the parameters being calculated at present.
Examples in Figs. 4C28 and 4C29 :
MANAGEMENT DATA NOZ. BYPASS RATE 25/500: Numerator 25 shows
the number of pick-up errors detected before 500 components are picked up.
Denominator 500 shows that 500 components are to be picked up. When 25
pick-up errors are detected, a message appears in the “MGT. INFO.” text box,
indicating that the pick-up rate has deteriorated and the nozzle is automatically
bypassed. When the number of pick-up errors does not reach “25” after 500
components are picked up. XX/XX is reset to “00/00” and counting starts
again.
The “NOZZLE BYPASS RATE (SAVED DATA)” shows the parameters just
before this delimiter.
When a nozzle is automatically bypassed, the blue head No. related to the
bypassed nozzle turns red at the “NOZZLE BYPASS RATE (SAVED
DATA)” display.
3-25
3.2 Component Handling Error Rate Data
0305-001 Tg0860-PM-MM
3.3 Management Data (Type 1)
Keys and menus related to production performance of the machine are pro-
vided, enabling the checking of overall performance data.
When the [MANAGEMENT DATA (TYPE 2)] key is pressed at the “MAN-
AGEMENT DATA” display, the “MANAGEMENT DATA (TYPE 2)” dis-
play appears, enabling the checking of almost the same items as those of the
“MANAGEMENT DATA (TYPE 1)” display. Distinguish between manage-
ment spans and check the required items.
When the [MANAGEMENT DATA (TYPE 1)] key is pressed at the “MAN-
AGEMENT DATA” display, the following display appears on the screen.
3-26
3.3 Management Data (Type 1)
Fig. 4C30
0305-001 Tg0860-PM-MM
3.3.1 MACHINE PERFORMANCE DATA
When the [MACHINE PERFORMANCE DATA] key is pressed at the “MAN-
AGEMENT DATA (TYPE 1)” display, the following display appears on the
screen.
This display looks similar to the “PATTERN PROGRAM MANAGEMENT
DATA - MACHINE PERFORMANCE DATA” display. Eachparameter is
based on management data of the machine (not on each pattern program).
(Refer to “3.1 (2) Machine Performance Data” for details.
3.3.2 SUB-SYSTEM ERROR COUNTS
When the [SUB-SYSTEM ERROR COUNTS] key is pressed at the
“MANAGEMENT DATA (TYPE 1)” display, the following display ap-
pears on the screen.
Shown is the total number of errors which occurred on each device
during automatic operation.
When each data key is pressed, the corresponding display appears, enabling
the checking of detailed information of the selected device or function where
an error(s) occurred.
3-27
3.3 Management Data (Type 1)
Fig. 4C31
Fig. 4C32