Operating Manual - 第30页

4022 591 960 62 Operating Manual 02.0 2 FCM Mu ltif lex 28 Switch-On Procedure 13.Safety swit ches ch eck ■ Check if the servo pow er indicator turns o ff after: 1. Pu shin g each in divi dual em erg e nc y stop butto n.…

100%1 / 80
4022 591 96062 Operating Manual
02.02 FCM Multiflex 27
Switch-On Procedure
10.
FIGURE 44
11.Push the servo button.
FIGURE 45
12.Check if servo power indicator is on.
(If not check if the run-in and run-out cover, all placement modules and
safety caps are closed and feeder trolleys and safety covers placed on the
FCM.)
CHECK
2
1
4022 591 96062 Operating Manual
02.02 FCM Multiflex 28
Switch-On Procedure
13.Safety switches check
Check if the servo power indicator turns off after:
1. Pushing each individual emergency stop button.
2. Removing each individual feeder trolley.
3. Opening each individual placement module.
4. Opening the run-in cover.
5. Opening the run-out cover.
6. Opening each individual safety cap (if present).
7. Removing each individual safety cover (if present).
Push the servo power button after each check.
FIGURE 46
7
6
55
4
3
2
1
1
4022 591 96062 Operating Manual
02.02 FCM Multiflex 29
Pre Start Inspections
CHAPTER 5 Pre Start Inspections
In case of an error, call for assistance.
1. Raise modules.
FIGURE 47
2. Empty all dumping bins.
FIGURE 48