4022 591 96062 Operating Manual
02.02 FCM Multiflex 56
New Program Selection
3. Select Command - Exchange nozzle.
SCREEN 35
4. Select All Enabled LAS Modules to lower all nozzles or one LAS module
only to lower a specific nozzle. Select OK
SCREEN 36
5.
SCREEN 37
6. Lift the Compact Laser Modules
FIGURE 98
4022 591 96062 Operating Manual
02.02 FCM Multiflex 57
New Program Selection
7. Select Lower MUP” “F5 or press F5 (MUP will be sent down).
SCREEN 38
8. For the first Compact Laser Module where a nozzle has to be exchanged:
Remove nozzle and brush
FIGURE 99
9. Place the calibration nozzle, take care for O-ring and spring be sure the
flange is against the MUP. If not, turn and push.
FIGURE 100
4022 591 96062 Operating Manual
02.02 FCM Multiflex 58
New Program Selection
10.Repeat action remove nozzle untill place new nozzle for all Compact
Laser Modules where calibration nozzles have to be exchanged
11.Select Done (MUP will move up)
SCREEN 39
12.Close the Run-in and Run-out cover.
FIGURE 101