4022 591 960 62 Operating Manual 02.0 2 FCM Mu ltif lex 70 Err or Handling 6. If th e probl em can not be solv ed: • Select ‘ Skip a ction [F1 1] ’ to sk ip th e sel ected acti on. The FCM st ops this compon ent pla ce m…

4022 591 96062 Operating Manual
02.02 FCM Multiflex 69
Error Handling
CHAPTER 11 Error Handling
11.1 Error Handling
In case of an error, this can be noticed.
■ The machine will stop.
■ The blue warning light.
■ Warning beeps.
■ The status display will change to Error.
■ The module with an error will turn red in the status window
FIGURE 114
1.
SCREEN 51
2. The dialogue shows all process errors.
3. If an error message is not clear, select the message and press ‘F1’
(activates the Help Screen).
In case of an SVS Pro error: select the error on the scanner.
When a position indicator is scanned the first error or warning on the
concerning feeder trolley is selected.
4. Solve the problem.
5. After the problem is solved:
■ Select ‘Retry all [F3]’ to retry all displayed errors.
■ Select ‘Retry [F7]’ to retry only the selected error(s).

4022 591 96062 Operating Manual
02.02 FCM Multiflex 70
Error Handling
6. If the problem can not be solved:
• Select ‘Skip action [F11]’ to skip the selected action. The FCM stops
this component placement on the board.
SCREEN 52
• Select ‘Skip board [F12]’ to stop further production of this board.
SCREEN 53
CAUTION
SELECTING ‘SKIP ACTION’ OR ’SKIP BOARD’ LEADS TO INCOMPLETE
BOARDS AT THE FCM RUN-OUT. THE MESSAGE ‘SUSPECTED BOARD IN
RUN-OUT SECTION’ APPEARS. REMOVE OR MARK THE BOARD.
7. The Error Cause Dialogue appears if this function has been enabled in the
’MIS-Parameters’. Select an error cause. After selection the error recovery
action will be performed.
SCREEN 54

4022 591 96062 Operating Manual
02.02 FCM Multiflex 71
Error Handling
8. If the error could not be recovered after ’Retry’ or ’Retry all’ the following
Screen appears.
SCREEN 55
9. Select ’OK’ to go back to the ’Error Recovery Dialogue’.
SCREEN 56
10.In case the problem can not be solved, call for assistance.
11.2 Possible Errors and Solutions
Most frequent occurring errors:
1. Miss SMD after pick
2. Misalign SMD
3. Pick-up Error / Y pick offset too large
4. Feeder problem.
5. Laser beam obstructed
6. Cal high or cal low surpassed.
7. Unexpected board in run in section
8. Board stuck in run in or run out section:
9. Fiducial measurement fail
Their most likely solutions are:
1. Miss SMD after pick
■ Empty feeder.
■ Too many empty pockets in tape.
■ Wrong nozzle type.
■ Wrong component type.
■ Dirty nozzle.
2. Misalign SMD
■ Wrong component type.
3. Pick-up Error / Y pick offset too large
■ Feeder trolley not mounted properly.
■ Feeder not mounted properly.
■ Index on feeder not correct.