Retrofitting and Maintenance Instructions SIPLACE HS-50 Fan with Increased Power,incl. AirFilter Box
Issue 07/01 2.2 Retrofit Kit and Tools, etc.
25
2.2 Retrofit Kit and Tools, etc.
NOTE:
The "Air filter box" retrofit kit only contains the parts for ONE fan box.
As a result, you always need 2 retrofit kits for each HS-50 machine, as listed below.
The fan with increased power is notincluded in this set, so it must either be taken to the customer
in addition. 2
The "air filter box assembly" retrofit kit, Item no. 00119016-01, contains:
-
--
- 1 pcs. air filter box, preassembled, Item no. 00357968-02:
1 pce. cover, compl. Item no. 00358284-02
1 pce. tray Item no. 00358285-02
2 pcs. Velcro strip "Klettostar-Haft 1365" Item no. 00357969-02
2 pcs. Velcro strip "Klettostar-Haft 1365" Item no. 00357970-02
2 pcs. O-ring 92x3 Item no. 00358739-01
6 pcs. Rapid clamping
element C2740 DC Item no. 00358751-02
1 pcs. Filter mat 230x360
(mounted on the frame) Item no. 00315209-01 *)
1 pcs. Adhesive label for air filter box Item no. 03000361-01
2 pcs. contact washer M4, SN 70093 Item no. 00362571-01
-
--
- 2 pcs. gantry-fan X motor
HS-50 option (with cable and plug Item no. 00364951-01
-
--
- 1 pcs. Retrofitting and Maintenance
Instructions "Air filter box, incl.
fan with increased power" HS-50, G + E Item no. 00193279-01
*) The filter mat is also required for maintenance (see Sec. 2.5.4).
Tools and consumables:
-
--
- For retrofitting: Driver for hexagon socket head screws, size 2.5 mm
-
--
- For retrofitting: Clean, lint-free cloth
-
--
- For maintenance: Vacuum cleaner with wide nozzle
Fan with Increased Power, incl. Air Filter Box Retrofitting and Maintenance Instructions SIPLACE HS-50
2.3 Safety Instructions Issue 07/01
26
2.3 Safety Instructions
2.3.1 Safety Instructions for the Retrofitting Procedure
DANGER
Retrofitting is only allowed to be carried out by SMD service engineers of Siemens Dematic AG.
Comply with the higher ranking "Safety Instructions" in Chapter "Operational Safety" in the User
Manual and Service Manual.
The machine SIPLACE HS-50 is powered by
219/380 V +/- 5% or
230/400 V +/- 5% or
239/415 V +/- 5% or
117/204 V +/- 5% or
133/230 V +/- 5%,
50/60 Hz line voltage.
Portions of the system are therefore conducting dangerous electricity, inside the machine even
while the master switch is turned off.
After you have properly carried out the shut-down of the Windows operating system NT:
BEFORE all work the machine must be turned OFF at the main switch and isolated from the
mains. In addition, the compressed air supply must be turned off at the main valve of the
compressed air unit in the machine base. There is no need to undock the changeover tables for
this retrofit. If you do this nevertheless, the compressed air lines must be bled by actuating the
needle valve at the compressed air unit for retrofitting (particularly due to the risk of injury - posed
by residual air - at the pneumatic cutter and because of the work required in the compressed air
branch).
In particular when working on the fanas described here,you must makesure before starting work
that both fans are de-energized and have stopped turning.
Obey the applicable accident prevention regulations, DIN standards and special safety codes of
your country at all times. DIN EN 60204, part 1, must be adhered to during all work inside the
machine base.
Follow the instructions regarding residual voltages in Chapter "Operational Safety"
Comply with regulations on ESDs (see Chapter "Operational Safety").
Continuation of the DANGER text see next page:
Retrofitting and Maintenance Instructions SIPLACE HS-50 Fan with Increased Power,incl. AirFilter Box
Issue 07/01 2.3 Safety Instructions
27
DANGER text continued:
During the whole work of retrofitting secure the machine conscientiously against other personnel
and prevent it from being turned back on without authorization, as described in the User Manual
in the chapter "Locking the Machine...".
The SITEST program is NOT needed during this retrofit.
The SIPLACE program is only to be started by personnel who are specially training by Siemens
Dematic AG and are thereby authorized to use the SITEST program. 2
2.3.2 Dangers Posed by Permanent Magnetism
The protective hoods remain closed during the retrofit and the maintenance. 2