00193279-01 - 第29页

Ret ro fitti ng an d Ma inte nanc e I nstruc tions SI PLA CE HS -50 Fan wit h Inc reas ed Po wer, incl . A ir Filte r Bo x Issu e 0 7/01 2.4 Retro fit ting Pro cedur e 29 2.4 Retr ofitting Pr ocedure 2.4. 1 Prep aring Bo…

100%1 / 40
Fan with Increased Power, incl. Air Filter Box Retrofitting and Maintenance Instructions SIPLACE HS-50
2.3 Safety Instructions Issue 07/01
28
2.3.3 Definitions
DANGER
in terms of these instructions means that death, severe bodily injury or considerable material
damage WILL occur if the instructions about danger are not followed. 2
2
WARNING
in terms of these instructions means that death, severe bodily injury or considerable material
damage may occur if the warnings are not heeded. 2
2
CAUTION
in terms of these instructions mean that minor bodily injury or material may occur if the cautions
are not heeded. 2
2
NOTE:
in terms of these instructions is a statement of important information about the product or the
pertinent portion of the instructions to which particular attention is being drawn. 2
2
Retrofitting and Maintenance Instructions SIPLACE HS-50 Fan with Increased Power,incl. AirFilter Box
Issue 07/01 2.4 Retrofitting Procedure
29
2.4 Retrofitting Procedure
2.4.1 Preparing Both Air Filter Boxes
Perform the following jobs in advance so that you do not need to interrupt production more than
necessary. 2
à Pick up the preassembled air filter box (Item no. see Sec. 2.2).
à Press gently against the lug on the long side of the tray (see Fig. 2.5.1) and lift the cover off
the tray of the air filter box.
NOTE:
The self adhesive Velcro strips (L = 194 and 360), Item no. see Sec. 2.2, are already stuck onto
the cover frame.
The uncovered central strut of the frame must be pointing downwards in the installation position.2
à Place the filter mat (Item no. see Sec. 2.2), which is already attached to a filter frame when
delivered, on the cover frame so it is flush with the outside edges of the frame all the way
around.
à Press the filter mat (with frame) against the Velcro strips along the outside edges.
à Also perform the steps described above for the second air filter box which you are going to
retrofit.
Fan with Increased Power, incl. Air Filter Box Retrofitting and Maintenance Instructions SIPLACE HS-50
2.4 Retrofitting Procedure Issue 07/01
30
Fig. 2.4.1 Mounting the O-ring Seals on Both Perforated Collars of the Tray
à Put down the air filter box so the curved surface is pointing downwards, as shown above.
à At each circular cut-out, pull an O-ring seal (Item no. see Sec. 2.2) onto the perforated collar.
2.4.2 Switching the Machine Off
DANGER
Retrofitting is only allowed to be carried out by SMD service engineers of Siemens Dematic AG.
Comply with all of the safety instructions in Sec. 2.3.
The machine remains in the line. The component changeover table remains docked. 2
à Stop the placement sequenceat a suitable pointandshut down theoperating system Windows
NT.
à Turn the machine OFF at the main switch.
à Isolate the machine from the mains.
à During the entire retrofitting sequence, secure the machine against unauthorized reactivation
as described in the Chapter "Locking the Machine..." in the User Manual SIPLACE HS-50
à With a visual check make certain that both the fans have stopped.
Tray
O-ring seal
Perforated collar
Notched recess