Paste With Board This parameter gives the option to dispense paste with a board loaded and held
at print height. This prevents paste dropping through the image on the screen.
Options are:
NOTE
With enabled selected the parameter Paste While Clean is removed.
Alternate Disp This parameter gives the option to dispense at either ENDS or CENTRE. ENDS
dispenses at the outer 25% of the squeegees. CENTRE dispenses along an area
of 25% either side of the centre line.
Alternate Disp
Rate
This parameter enables the user to select the ratio of alternate dispenses to
standard dispenses.
Paste Recovery
Rate
This parameter sets the frequency, measured in print strokes completed in either
direction, at which paste roll recovery occurs in both directions, when using
squeegees.
Front Paste
Recovery
This parameter sets the extent of paste roll recovery movement while beginning
the rearward print stroke. The movement is measured forward from the print
stroke start position.
Options Available
Enabled
Disabled
Options Available
Ends
Centre
No Alternate Dispense Every Dispense Every Second Dispense etc.
Minimum Maximum Increment Default
0
(This disables paste
roll recovery)
500 1 1
Minimum Maximum Increment Default
0.0mm 15.0mm
(Subject to front turn-
around envelope)
1.0mm 5.0mm
INFINITY
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 7 User Manual 1.99
Rear Paste
Recovery
This parameter sets the extent of paste roll recovery movement while beginning
the forward print stroke. The movement is measured rearward from the print
stroke start position.
Screen Clean Mode
1 (including
Vacuum)
This parameter sets the mode of operation of the screen cleaner for the first clean
mode. When selected this parameter opens a window that allows a screen clean
option sequence to be chosen. The sequence includes six stages, each of which
may be one of the following cleaning operations:
Screen Clean
Rate 1
This parameter sets the number of print cycles between the cycling of the screen
cleaner for the first screen clean rate.
Screen Clean Mode
2 (including
Vacuum)
This parameter sets the mode of operation of the screen cleaner for the second
clean mode. When selected this parameter opens a window that allows a screen
clean option sequence to be chosen. The sequence includes six stages, each of
which may be one of the following cleaning operations:
Screen Clean
Rate 2
This parameter sets the number of print cycles between the cycling of the screen
cleaner for the second screen clean rate.
Minimum Maximum Increment Default
0.0mm 15.0mm
(Subject to rear turn-
around envelope)
1.0mm 5.0mm
Cleaning Operation Note
Wet A warning is given if the end stroke is wet.
Dry
Vac
None
Minimum Maximum Increment
0 (Screen cleaner off) 200 1
Cleaning Operation Note
Wet A warning is given if the end stroke is wet.
Dry
Vac
None
Minimum Maximum Increment
0 (Screen cleaner off) 200 1
INFINITY
0$&+,1(352*5$00,1*
0(183$5$0(7(56
1.100 User Manual Software Version 7
Vortex Cassette
Life (Vortex USC)
This parameter sets the number of cleaning strokes that are applied before a
cleaning cassette is replaced.
Vortex Clean Rate
(Vortex USC)
This parameter sets the frequency (in print cycles) at which screen cleaning
occurs.
Vortex Solvent
Rate (Vortex USC)
This parameter sets the frequency (in cleaning cycles) at which solvent is
dispensed.
Vortex Vacuum
Start (Vortex USC)
The distance, in from the front edge of the board, where vacuum is applied.
Vortex Vacuum
Stop (Vortex USC)
The distance, in from the front edge of the board, where vacuum application is
stopped.
Vortex Vacuum
Rate (Vortex USC)
This parameter sets the frequency (in cleaning cycles) at which vacuum is
applied.
Vortex Vacuum
Period (Vortex
USC)
This parameter sets the period for which vacuum is applied.
Minimum Maximum Increment Default
0.0 200.0 1.0 20.0
Minimum Maximum Increment Default
0.0 200.0 1.0 0.0
Minimum Maximum Increment Default
1.0 10.0 1.0 1.0
Minimum Maximum Increment Default
Vacuum Stop Board Width 1.0 0.0
Minimum Maximum Increment Default
-100.0mm Vacuum Stop 1.0mm 0.0mm
Minimum Maximum Increment Default
1.0 10.0 1.0 1.0
Minimum Maximum Increment Default
1.0 sec 10.0 secs 1.0 sec 5.0 secs