DEK INFINITY USER MANUAL - 第104页

INFINITY 0$&+,1( 352*5$ 00,1* 0(183$5$ 0(7(5 6 1.102 User Manual Software Versi on 7 V a c Clean Speed This parameter sets the speed of the screen clean vacuum for optimization. Fr ont Start Offset (Blue U SC) This…

100%1 / 356
INFINITY
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 7 User Manual 1.101
Clean After Knead This function is active if the machine is running in automatic mode. If this
option is enabled and a paste dispense has been performed (either MANUAL or
AUTOMATIC) a paste knead is performed as defined by the paste knead
parameters in the board file on the next board immediately following the paste
dispense. When selected this parameter opens a window that allows a clean after
knead option sequence to be chosen. The sequence includes six stages, each of
which may be one of the following cleaning operations:
Clean After
Downtime
This function provides the facility for the screen to be cleaned automatically
with a preprogrammed clean after a preprogrammed idle time. Clean After
Downtime only becomes active after the machine has performed at least one
print after it is powered up. When selected this parameter opens a window that
allows a clean after knead option sequence to be chosen. The sequence includes
six stages, each of which may be one of the following cleaning operations:
Clean After The Automatic screen clean after downtime process chosen in the above menu
parameter is carried out after a countdown of the number of minutes set in this
parameter.
Dry Clean Speed This parameter sets the speed of the screen clean dry wipe for optimization on
the Blue USC and the speed of the screen clean return stroke on the Vortex USC.
Wet Clean Speed This parameter sets the speed of the screen clean wet wipe for optimization.
Cleaning Operation Note
Wet A warning is given if the end stroke is wet.
Dry
Vac
None
Cleaning Operation Note
Wet A warning is given if the end stroke is wet.
Dry
Vac
None
Minimum Maximum Increment
5.0 mins 120.0 mins 1.0 min
Minimum Maximum Increment
10.0mm/sec 120.0mm/sec 1.0mm/sec steps
Minimum Maximum Increment
10.0mm/sec 100.0mm/sec 1.0mm/sec steps
INFINITY
0$&+,1(352*5$00,1*
0(183$5$0(7(56
1.102 User Manual Software Version 7
Vac Clean Speed This parameter sets the speed of the screen clean vacuum for optimization.
Front Start Offset
(Blue USC)
This parameter determines the distance from the front edge of the board that the
cleaning stroke must start.
Front Start Offset
(Vortex USC)
This parameter determines the distance from the front edge of the board that the
cleaning stroke must finish.
Rear Start Offset
(Blue USC)
This parameter determines the distance from the rear edge of the board that
cleaning must complete.
Rear Start Offset
(Vortex USC)
This parameter determines the distance from the rear edge of the board that
cleaning must start.
Stop After Idle This parameter when enabled sets the time the product is held in contact with
the screen until both upline and downline systems are ready to transfer.
Paste Knead Period This parameter sets the time period between print cycles which, if exceeded,
initiates a paste knead sequence.
Knead Deposits This parameter sets the number of print strokes to be carried out on each of the
kneaded boards.
Minimum Maximum Increment
10.0mm/sec 100.0mm/sec 1.0mm/sec steps
Minimum Maximum Increment
0.0mm 60.0mm 1.0mm
Minimum Maximum Increment Default
-60.0mm 60.0mm 1.0mm 30.0mm
Minimum Maximum Increment
0.0mm 60.0mm 1.0mm
Minimum Maximum Increment Default
-60.0mm 60.0mm 1.0mm 30.0mm
Minimum Maximum Increment
0.0 mins 200.0 mins 1.0 min
Minimum Maximum Increment
0 (paste kneading switched off) 30 minutes 1 minute
Minimum Maximum Increment
2201
INFINITY
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 7 User Manual 1.103
Knead Boards This parameter sets the number of boards to be printed using the knead sequence.
Knead After
Dispense
If this option is enabled and a paste dispense has been performed (either Manual
or Automatic) a paste knead is performed (as defined by the paste knead
parameters in the board file) on the next board immediately following the paste
dispense.
ProFlow Cassette This parameter sets the size of the transfer head used by the ProFlow unit. Size
may be one of the following:
NOTE
For 350mm and 450mm transfer heads, set to 400mm and 500mm respectively.
ProFlow System
Pressure
This is the amount of print pressure (downward force) applied onto the stencil
by the ProFlow unit.
ProFlow Paste
Pressure
This is the pressure applied to paste in the ProFlow unit while kneading and
printing.
NOTE
Only available if the Software Controlled Air Regulator (SCAR) is fitted.
ProFlow Idle
Pressure
This is the pressure applied to paste in the ProFlow unit between kneading and
printing and between print strokes.
NOTE
Only available if the Software Controlled Air Regulator (SCAR) is fitted.
Minimum Maximum Increment
1101
Options Available
Enabled
Disabled
Size
300.0mm
400.0mm
500.0mm
Minimum Maximum Increment Default
0.0Kg 20.0Kg 0.2Kg 0.0Kg
Minimum Maximum Increment Default
0.2 bar 4.0 bar 0.2 bar 2.0 bar
Minimum Maximum Increment Default
0.0 bar 4.0 bar 0.2 bar 0.4 bar