DEK INFINITY USER MANUAL - 第132页
INFINITY 6(735()(5(1 &(6 35()(5(1&(6 2.6 User Manual Software Version 7 End Maintenance Pressure Recalibrated Offset Recalibrated XY Scale Recalibrated Theta Recalibrated Configuration Changed Start Diagnostics …

INFINITY
6(735()(5(1&(6
35()(5(1&(6
Software Version 7 User Manual 2.5
Setting Up Events The Event Recording menu is laid out as follows:
Use the Next and Previous keys to move to the event to be changed.
Use the Toggle key to toggle the Disk and Host parameters between on and off.
Use the Left and Right keys to move to the Disk, Host or Grp columns.
Use the Incr. and Decr. keys to change the value of the Grp parameter.
Use Exit to leave the Event Recording window.
Recordable Events The following tables show the events that can be selected for recording:
Toggle Left Right Next Previous Incr. Decr.
Exit
System Power On System Power Down Humidity
Temperature Batch Count Measured Cycle Time
Throughput Cycle Time Front Print Pressure Rear Print Pressure
Table Separation Speed Stretch Error X Error
Y Error Theta Error Board Fid 1 Score
Board Fid 2 Score Board Fid 3 Score Screen Fid 1 Score
Screen Fid 2 Score Screen Fid 3 Score ProFlow System Pressure
Pneumatic Power Down Front Squeegee Error Rear Squeegee Error
Rising Table Error Print Carriage Error Paste Carriage Error
Camera X Axis Error Camera Y Axis Error Rail Width Error
Screen XF error Screen XR Error Screen Y Error
Paste Cartridge Tilt Error Screen Changer Drive Error Board Stop Stuck
Board Clamp Stuck Board Stuck In Rails Unable To Find Fiducial
Rail Lifted Error Pressure Error File Error
Unable To Recover Recovery Started Recovered
Upline Transfer Error Downline Transfer Error Dual Shuttle Fault
Screen Elevator Comms Fault Screen Elevator Fault Screen Changer Fault
Lid Bolt Fault Alignment Out Of Range Line Power On
Line Power Off Cover Open Cover Closed
Printer Ready Head Raised Head Closed
Paste Dispensing Paste Cartridge Empty Cycle Aborted
Cycle Completed Cleaning Screen Parameter Adjusted
Setup Started Product Loaded New Product
Product Data Changed Screen Unloaded Screen Loaded
Tool Change Started Tool Change Complete Setup Ended
Start Print Cycle Board Received End Print Cycle
Printed Board Ready Board Printed Operator Log On
Operator Log Off Clear Batch Count Start Maintenance

INFINITY
6(735()(5(1&(6
35()(5(1&(6
2.6 User Manual Software Version 7
End Maintenance Pressure Recalibrated Offset Recalibrated
XY Scale Recalibrated Theta Recalibrated Configuration Changed
Start Diagnostics End Diagnostics Flood Height Reset
Camera Ref Reset Thickness Recalibrated Vision Height Reset
Print Height Reset AutoFlex Status Reset Software Updated
New Event Log Front Reference Position Reset Front Reference Height Reset
Rear Reference Height Reset Check Cleaner Paper Cleaner Solvent Low
Barcode Read Failure Barcode Mismatch Screen Couplings Not Extended
Mint Reply Timeout Camera X Failed To Position Camera Y Failed To Position
Aperture Blockage Stencil Smear Paste Present
Bridging alarm Alignment Alarm Head Left Partly Open
Head Moved To Safe State Inspection Cycle Complete Clock Change Request
Clock Changed Board Delivered and Removed Event Log Disc File Full
ProFlow Error Autoflex Tooling Selected Autoflex Tooling Deselected
AutoFlex Tooling Enabled AutoFlex Tooling Disabled Tooling Data Has Been Changed
CAN Node Comms Lost. Node CAN Node Comms Active. Node CAN Bus Comms Lost. Bus
CAN Bus Comms Active. Bus Invalid CAN Response Product Directory Request
Current Product Request Erase Product Request Rename Product Request
Load Product Request Download Product Request Upload Product Request
Download Configuration Request Upload Configuration Request Upload Management Data Request
Clear Batch Data Request Clear Session Data Request Upload Event Log Request
Clear Event Log Request Comms Start Request Comms Stop Request
Update Mode Request Comms Error Parameter Info Uploaded
Formatted Parameters Uploaded Formatted Parameters Downloaded Comms Status Request
Comms Rebuild Product List Comms Adjust Paste Rate Comms Adjust Front Pressure
Comms Adjust Rear Pressure Comms Adjust Print Gap Comms Adjust Separation Speed
Comms Adjust Clean Screen Comms Adjust FWD_X Offset Comms Adjust FWD_Y Offset
Comms Adjust FWD_T Offset Comms Adjust REV_X Offset Comms Adjust REV_Y Offset
Comms Adjust REV_T Offset Comms Dispense Paste Request Comms Clean Screen Request
Comms Enabled Comms Disabled Equipment Constant Change
Acknowledge Terminal Message Comms Knead Paste Request Comms Condition Paste Request
Control State Change To Local Control State change To Offline Control State Change To Remote
GEM Spooling Activated Gem Spooling Deactivated GEM Spool Transmission Failure
Operator Command Issued Remote Barcode Received Comms Adjust ProFlow Pressure
Options.enb file Attribute Error Volume Alarm Evaluation Dongle Detected
Valid Dongle Detected Dongle Error Dongle Changed
Print Speed Front Print Speed Rear Print Speed
Comms Adjust Print Speed Comms Adjust Front Print Speed Comms Adjust Rear Print Speed

INFINITY
6(735()(5(1&(6
35()(5(1&(6
Software Version 7 User Manual 2.7
Tooling Hardware Sets which type of tooling is fitted, these options are:
Fiducial Reference Sets whether the fiducial co-ordinates are specified relative to the front/left or
front/right corner of the board, options are:
Product Barcode
Hardware
Sets whether or not the product barcode reader is fitted, options are:
Screen Barcode
Hardware
Sets whether or not the screen barcode reader is fitted, options are:
Remote Barcode
Hardware
This preference is only available if the TCP/IP version of Host Comms is used
and Serial Host Comms is not selected from the Comms Protocol set preference,
options are:
Vortex Cassette Replaced Maintenance Monitoring Initials The Monthly Service is Due
The Six Monthly Service is Due The Yearly Service is Due Equipment Recovery
Equipment Setup Equipment Ready Equipment Maintenance
Equipment Waiting Equipment Running Equipment Down
Camera Behind Rail Unload Board Start
Options
Vacuum
Magnetic
AutoFlex
Vac for Flex
Options
Left
Right
Options
Fitted
Not Fitted
Options
Fitted
Not Fitted
Options
Fitted
Not Fitted