DEK INFINITY USER MANUAL - 第164页

INFINITY (552 50( 66$*(6 (552 50( 66$*( /,67 ,1* 4.4 User Manual Software Version 7 Command T imed Out (Camera Axes) This error re ports that the camera has failed to move to the deman ded position within the time per…

100%1 / 356
INFINITY
(55250(66$*(6
(55250(66$*(/,67,1*
Software Version 7 User Manual 4.3
ERROR MESSAGE LISTING
Error Message Interpretation
Alignment Out of Range This indicates that the actuator positions required to achieve a satisfactory
alignment are not attainable.
Alignment Close to Limit/Out of Range Actuator limit exceeded.
AutoFlex Timed Out This error reports that with AutoFlex tooling on high power and the tooling
pins up, the process time of 5 minutes has been exceeded. When this
message is displayed the power is also switched to low.
Board Detected At Board Stop, Print
Terminated.
With the machine running in any mode, this error reports that the board
stop sensor has been activated out of sequence.
Possible causes are:
Board already loaded into the machine.
Sensor is detecting tooling.
Sensor is faulty.
Board Fiducial Not Found This error reports that the vision system has been unable to locate the
board fiducial.
Board Not Over Input Sensor This error reports a machine has started without a board on the rails. The
user has ignored the message to place a board on the rails and selects
continue on the machine.
Board On Rails, Remove and Continue This error reports that a board has been sensed on the rails during one of
the following operations:
Initialization
Loading a new board file
Entering the rail system in diagnostics.
Board Stop Not Lowered This error reports that the board stop is up and has not lowered within the
time-out period of 3 seconds. The possible causes are: Board stop sensor
- enter Diagnostics and check the sensor changes state.
Air pressure failure to the board stop.
Board Stop Not Retracted This error reports that the board stop is down and has not retracted within
the time-out period of 3 seconds. A possible cause is:
Board stop sensor - enter Diagnostics, Digital Inputs and check the sensor
changes state.
Board Stop Stuck This error reports that the board stop, which is housed in the camera
assembly has failed to lower or retract.
Board Stuck in Rails This error reports that the board has failed to either reach the board stop
or exit the machine after being printed.
Camera X Axis Error This error reports that the camera carriage has failed to reach its home
position in the X axis.
Camera Y Axis Error This error reports that the camera carriage has failed to reach its home
position in the Y axis.
Command Timed Out
(Belt Motors)
This error reports if a board on the belt fails to move over the board at left/
right sensor within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
INFINITY
(55250(66$*(6
(55250(66$*(/,67,1*
4.4 User Manual Software Version 7
Command Timed Out
(Camera Axes)
This error reports that the camera has failed to move to the demanded
position within the time period. This error applies to both the X and Y
camera axis. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Paste Dispense Carriage)
This error reports that the paste dispense carriage has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed out
(Print Carriage)
This error reports that the print carriage has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Print Head)
This error reports that the print head fails to move to the demanded
position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(ProFlow)
This error reports that the ProFlow unit has failed to move to the demanded
position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Rail System)
This error reports that the moving rail has failed to move to the demanded
position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Screen Actuators)
This error reports that the actuator has failed to move to the demanded
position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Screen Change)
This error reports that the screen change has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Error Message Interpretation
INFINITY
(55250(66$*(6
(55250(66$*(/,67,1*
Software Version 7 User Manual 4.5
Command Timed Out
(Front/Rear Squeegee)
This error reports that the front/rear squeegee has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Downline Board Transfer Fault This error reports that the time the downline interface has waited for a
board has exceeded the time-out.
Downline Machine Not Available This error reports that the downline machine is unavailable to accept the
next board.
Dual Shuttle Fault This error reports that the 20 seconds time-out period has been exceeded
when loading or unloading a screen.
Event File Open Error This error reports that there was a problem opening the event log backup
file.
Failed to Determine Tooling Deviation This error reports that while monitoring the tooling deviation, the number
of samples (pressure variations) during the print stroke was less than 2 or
the minimum value was zero. This error message is only valid where
tooling deviation is authorized and enabled.
Check tooling support is sufficient.
Check underside components are clear of tooling.
Front Squeegee Error This error reports that the front squeegee has failed to reach its fully up
position.
Front Squeegee Pressure Error When this error is detected a new window displays the set pressure reading
and the actual pressure reading.
File Error This message appears if there is an error writing or reading a machine file.
Have All Tooling Pins Been Removed? This message appears for the user to confirm that all magnetic tooling pins
have been removed, before setting up the machine for a new board file that
uses AutoFlex tooling.
Invalid Calibration Data. Recalibrate
ProFlow Heights
This error reports that the ProFlow calibration data is corrupt or invalid.
Invalid Calibration Data. Recalibrate
Squeegee Heights
This error reports that the squeegee calibration data is corrupt or invalid.
Lid Bolt Fault This indicates that the lid bolt has failed to either open or close.
No Paste Knead Cycles Selected This error reports when Knead Paste is selected on main menu page and
Knead Deposits in Set Prefs is selected to 0 cycles.
Paste Carriage Error This error reports that the paste carriage has failed to reach its home
position.
Paste Cartridge Tilt Error This error reports that the paste cartridge mechanism has failed to either
make its up or down limit switches.
Pneumatic Power Down This error message reports that the pneumatic supply is either too low or
has been disconnected.
Position Error (Camera This error reports that the cameras actual position is not within the
tolerance of 1% of the designated position.
Position Error (Print Carriage) This error reports the print carriage actual position is not within tolerance
of its designated position.
Position Error (Rising Table) This error reports that the rising table has failed to reach its home position.
Error Message Interpretation