DEK INFINITY USER MANUAL - 第169页
INFINITY ',$*12 67, &6 ,1752'8& 7,21 Soft ware Ver sion 7 User Manual 5.1 CHAP TER 5 DIAGNOSTICS INTRODUCTION The diagnostic function is an aid to the user to allow individual access and control of moto…

INFINITY
(55250(66$*(6
(55250(66$*(/,67,1*
4.8 User Manual Software Version 7

INFINITY
',$*1267,&6
,1752'8&7,21
Software Version 7 User Manual 5.1
CHAPTER 5 DIAGNOSTICS
INTRODUCTION The diagnostic function is an aid to the user to allow individual access and
control of motors and modules. It allows the user to control the sequence of the
machine so that a particular module can be exercised.
To enter the diagnostic mode press the Maint button.
The menu bar changes displaying the Diagnostic option.
Press the Diagnost (F6) button. If a password exists a window displays the
message ‘Diagnostic Password’. If the password is incorrect control displays
the message‘Invalid password entered’ and returns to the previous menu. If
the correct password is entered or no password exists a pop up window displays
the following:
The menu bar changes displaying the following:
Next / Previous keys move the highlight bar up and down the list of diagnostic
modules.
Select Module key opens a new window displaying the diagnostic functions
available for the selected module.
Exit returns operation to the start of initialization.
NOTE
Before any diagnostic function is used in any of the modules they must be homed
first or they are not able to initiate a command.
Run Head
Paste
Load
Clean
Screen
Adjust Setup Monitor Maint.
Calibrat
Pressure
Calibrat
Offset
Calibrat
Vision
House
Keeping
Set
Prefs
Diagnost
Tes t
Cycles
Exit
Module Diagnostic Page
System
Print Head
Print Carriage
ProFlow / Squeegee
Camera Axes
Rail System
Paste Dispense System
Screen Alignment
Screen Change
Screen Cleaner
Rising Table
MIU
Autoflex Tooling
Select
Module
Next Previous Exit

INFINITY
',$*1267,&6
6<67(0
5.2 User Manual Software Version 7
SYSTEM Selecting this diagnostic module opens the following window:
The menu bar changes displaying the following:
Next / Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight bar.
Exit returns operation to the module diagnostic page.
Display All Digital
Inputs
Selecting this diagnostic function opens the following window:
System Diagnostics
ON
ON
ON
ON
OFF
Display all Digital Inputs
Display all Analogue Inputs
Toggle Red Beacon
Toggle Amber Beacon
Toggle Green Beacon
Toggle Lid Bolt
Data Logging
Change Edit Password
Change Diagnostics Password
Change Terminate Password
Change Adjust Password
Change Fiducial Set-Up Password
Change Maintenance Password
Terminate Control Program
Run
Diagnost
Next Previous Exit
Digital Group
NM 1 Group 0
NM 1 Group 1
NM 1 Group 2
NM 1 Group 3
NM 1 Group 4
MMOV 1 Group 0
MMOV 1 Group 1
MMOV 1 Group 2
MMOV 1 Group 3
MMOV 2 Group 0
MMOV 2 Group 1
MMOV 2 Group 2
MMOV 2 Group 3