DEK INFINITY USER MANUAL - 第184页

INFINITY ',$*126 7,&6 &$0(5$ $;(6 5.16 User Manual Software Versi on 7 CAMERA AXES Selecting this diagnostics module opens the following window: The menu bar changes to the following: Next / Previous keys m…

100%1 / 356
INFINITY
',$*1267,&6
648((*((
Software Version 7 User Manual 5.15
Pressure Reading This diagnostic function is a live display, showing the actual pressure being
applied to the squeegee. With no squeegees fitted the figure displayed varies
from machine to machine.
INFINITY
',$*1267,&6
&$0(5$$;(6
5.16 User Manual Software Version 7
CAMERA AXES Selecting this diagnostics module opens the following window:
The menu bar changes to the following:
Next / Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight bar.
Exit returns operation to the module diagnostics page.
Fiducial Setup enables screen fiducials to be located.
Adjust opens the following window:
The menu bar changes to the following:
Next / Previous keys move the highlight bar up and down the list of diagnostic
parameters.
Incr. / Decr. keys change the value of the selected diagnostic parameter.
Exit returns operation to the camera diagnostics page.
NOTE
These parameters are used in diagnostics only and have no affect on the product
board file.
ON
ON
.. more
Home Camera X Axis
Home Camera YAxis
Camera Axis To Fiducial 1 Position
Camera Axis To Fiducial 2 Position
Camera Axis To Fiducial 3 Position
Drive to Board Stop Position
Restore Default Reference Position
Drive to Reference Position
Set Reference Position
Move Camera X Axis Using Jog Buttons
Move Camera YAxis Using Jog Buttons
Initialise Vision System
Fiducial Lighting
Inspection Lighting
Camera Diagnostics
Run
Diagnost
Adjust
Fiducial
Setup
Next Previous Exit
FIDUCIAL 1 X
FIDUCIAL 1 Y
FIDUCIAL 2 X
FIDUCIAL 2 Y
FIDUCIAL 3 X
FIDUCIAL 3 Y
BOARD STOP X
BOARD STOP Y
CYCLE COUNT
Camera Cycle Test Parameters
243.0
241.1
7.3
8.8
0.0
0.0
125.0
165.0
50.0
mm
mm
mm
mm
mm
mm
mm
mm
Cycles
Next Previous Incr. Decr. Exit
INFINITY
',$*1267,&6
&$0(5$$;(6
Software Version 7 User Manual 5.17
Home Camera X
Axis
Selecting this diagnostic function drives the camera X carriage to its home
position, as determined by its home sensor.
Home Camera Y
Axis
Selecting this diagnostic function drives the camera Y carriage to its home
position, as determined by its home sensor.
Camera Axis to
Fiducial 1 Position
Selecting this diagnostic function drives both X and Y carriages to the position
set by the fiducial 1 X and Y coord parameters.
Camera Axis to
Fiducial 2 Position
Selecting this diagnostic function drives both X and Y carriages to the position
set by the fiducial 2 X and Y coord parameters.
Camera Axis to
Fiducial 3 Position
Selecting this diagnostic function drives both X and Y carriages to the position
set by the fiducial 3 X and Y coord parameters.
Drive to Board
Stop Position
Selecting this diagnostic function drives both X and Y carriages to the position
of the board stop for the current product.
Restore Default
Reference Position
Selecting this diagnostic function restores the reference position stored as a
default in software.
Drive to Reference
Position
Selecting this diagnostic function drives both X and Y carriages to the position
set by the camera X and Y reference parameters.
Set Reference
Position
Selecting this diagnostic function alters the printer configuration file after the
camera has been positioned, so that it is viewing the reference mark on the front
rail. On selection the menu bar displays Confirm, pressing this key alters the
printer configuration file. This is used in conjunction with move camera X and
Y axes. Refer to the Technical Reference Manual Camera and Vision System
Chapter for the camera reference position procedure.
Move Camera X
Axis Using Jog
Buttons
Selecting this diagnostic function moves the camera X axis using the jog
buttons. The right jog button drives the camera to the left at slow speed and the
left jog button drives the camera to the right, stopping immediately the button is
released. This is a physical movement of the camera, not as displayed on the
monitor.
Move Camera Y
Axis Using Jog
Buttons
Selecting this diagnostic function moves the camera Y axis using the jog
buttons. The right jog button drives the camera to the rear at slow speed and the
left jog button drives the camera forward, stopping immediately the button is
released. This is a physical movement of the camera, not as displayed on the
monitor.
Initialize Vision
System
Selecting this diagnostic function initializes the frame grabber board and it
displays a live image on the vision monitor and a superimposed box graphic.
Fiducial Lighting Selecting this diagnostic function alternately switches the fiducial lighting on
and off, continuously displaying the current status.